beautypg.com

Error messages, Warning messages – Panasonic AJ-SD955BP User Manual

Page 67

background image

67

Warning messages

Error messages

Priority

O

Monitor display

O

Description

O

VTR operation and corrective action

High

E-04 (UNKNOWN SIG)
This appears when the SDTI input signals are not
DVCPRO or DV format signals. (The data stream
format complies with the SMPTE 321M standard.)
VTR: No recording operations can be performed.

O

Check whether the SDTI input has been
connected properly.
(This warning is displayed when SDI signals are
being input.)

Priority

O

Monitor display

O

Description

O

VTR operation and corrective action

Low

E-01 (LOW RF)
This appears when envelope levels approximately
1/3 that of normal levels are detected for more than
one second during playback, recording, or editing.
VTR: Operation continues.

O

Clean the video heads.

E-02 (HIGH ERROR RATE)
This appears when the error rate has increased to
the extent that correction or interpolation was
performed on either the video or audio signals.
VTR: Operation continues.

O

Clean the video heads.

E-11 (NOT 1a25M SIG)
This appears when the SDTI input signals are not
DVCPRO (25 Mbps) format 1a transfer signals.
VTR: No recording operations can be performed.

O

Check the SDTI input signals.

E-12 (NOT 1a50M SIG)
This appears when the SDTI input signals are not
DVCPRO50 (50 Mbps) format 1a transfer signals.
VTR: No recording operations can be performed.

O

Check the SDTI input signals.

E-00 (SERVO NOT LOCKED)
This appears when the servo is not locked for three
or more seconds during playback, recording, or
editing.
VTR: Operation continues.

O

Check the tape.
A tape recorded other than NTSC format may
have been inserted.

E-16 (INVALID VIDEO SIG)
This appears when the compressed video signals in
the SDTI input signals are invalid.

O

This warning appears only during recording
operations. In cases like this, no signals are
recorded on the tape and only the erasure of the
existing signals will be performed.

VTR: Operation continues.

No editing operations can be performed.

O

Check the SDTI input signals.
Playback signals of tape on which material has
not been recorded may be being input.

E-17 (INVALID AUDIO SIG)
This appears when the audio signals in the SDTI
input signals are invalid.

O

This warning appears only during recording
operations. In cases like this, the signals are
recorded with the audio signals muted.

VTR: Operation continues.

No editing operations can be performed.

O

Check the SDTI input signals.
Signals from other than a VTR with 1a playback
may be being input.

E-18 (INVALID TC SIG)
This appears when the time codes in the SDTI input
signals are invalid.

O

This warning appears only during recording
operations. In cases like this, the internally
generated time codes are recorded.

VTR: Operation continues.

No editing operations can be performed.

O

Check the time code being input from the
components.

E-10 (FAN STOP)
This is displayed when the fan motor stops.
VTR: Operation continues.

O

Check that nothing is obstructing the fan
movement.

E-09 (NO RF)
This appears during playback when a blank section
(tape blank) lasting for one or more seconds has
been detected.
Such a section is identified as a tape blank when all
of the following conditions are met.

O

No head outputs

O

No playback data readout

O

No CTL (Excluding DV and DVCAM tapes)

VTR: Operation continues.

O

Check the tape.
A tape on which material has not been recorded
may have been inserted.