Attach the outer member brackets to the rack.
Check that the height is the same for the left and
right brackets.

3

Remove the four screws at the front for attaching
the left and right side panels.

4

Attach the AJ-MA75P rack mount adapter using
the same 4 screws.

1

Attach the inner members of the slide rails.
Refer to the figure below for the locations where
the screws are to be attached.

The unit can be mounted into a 19-inch standard rack
using the optional rack-mounting adaptors (AJ-
MA75P). For the installation rails, it is recommended
that the 18-inch rail and bracket (model number
CC3061-99-0400) by Chassis Trak be used. (The
complete slide rail and bracket unit is not available
from Panasonic.)
For further details, consult your dealer.

Rack mounting

O

The length of the screws used is subject to
restriction. (B, G: 10 mm, E: 6 mm)

O

Attach the inner members at the same
symmetrical positions on the left (L) side.

O

Fix the members in place using 3 screws on
each side (total: 6 screws).

O

The letters “A” to “H” are not actually marked on
the side panels.

Inner member

Locations where the screws are secured on the right
(R) side of the inner members of the slide rails

Rack-mounting adaptors

5

Remove the 4 rubber legs from the bottom of the
unit, and install the unit in the rack.
After the unit has been installed, check that it
moves smoothly along the rails.

Standard rack

Fasten it to the rack with set
screws.

O

Keep the temperature inside the rack to between
41°F to 104°F (5°C to 40°C).

O

Bolt the rack securely to the floor so that it will not
topple over when the VTR is drawn out.