Setup menus, User menu – Panasonic AJ-SD955BP User Manual
Page 47
47
Setup menus
The underlined items indicates the initial setting.
USER menu
No./Item
Description
623
SETUP 50
For setting 7.5% setup processing to be
performed on input and output signals in the
DVCPRO50 (50 Mbps) mode.
When the STOP button is pressed, operation is
transferred to the sub-screen, and the setup level
is set for each output. To return from the sub-
screen, press the STOP button again.
system.
00
CMPST IN
Sub-screen
This selects the 7.5% setup processing for
the input composite signal.
0000
THRU :
The signal is recorded in its original form.
0001
CUT :
The signal is recorded with the 7.5% setup
removed.
02
CMPNT IN
This selects the 7.5% setup processing for
the input component signal.
0000
THRU :
The signal is recorded in its original form.
0001
CUT :
The signal is recorded with the 7.5% setup
removed.
03
CMPNT OUT
This selects the 7.5% setup processing for
the output composite, component and serial
(digital) signal.
0000
THRU :
The signal is output in its original form.
0001
CUT :
The signal is output with the 7.5% setup
removed.
0002
ADD :
The signal is output with the 7.5% setup
added.
01
CMPST OUT
This selects the 7.5% setup processing for
the output composite signal.
0000
THRU :
The signal is output in its original form.
0001
ADD :
The signal is output with the 7.5% setup
added.
03 (CMPNT OUT) of setup menu item No. 623
(SETUP 50).
No./Item
Description
624
CC REC
For selecting whether to record the closed
caption signals multiplexed on the input
signals on the tape.
0000
OFF :
No closed caption signal is recorded.
In addition, the EE output signals are blanked.
0001
ON :
When a closed caption signal is detected from
the selected input signal, it can be recorded.
O
If SDTI/1394 signals have been selected as
the input signals, the closed caption signals
which have been multiplexed onto the input
signals will be recorded on the tape regardless
of the setting.
O
This setup menu is not displayed in the 625i
system.
660
UMID REC
This selects whether or not to record the
UMID information on the tape.
0000
OFF :
UMID information is not recorded on the tape.
In addition, EE output signals are blanked.
0001
ON :
UMID information is recorded on the tape.
O
If SDTI/1394 has been selected as the input
signals using the INPUT SELECT button, the
UMID information on the input signals will be
recorded regardless of this menu’s setting.
O
If THRU has been selected as the setup menu
item No. 106 (EE MODE SEL) setting, UMID
information of the EE output signals will be
blanked.
645
WIDE SELECT
This selects whether or not to record the
wide-screen information on the tape.
0001
WIDE :
The wide-screen information is not recorded on
the tape.
0002 NORMAL :
The wide-screen information is recorded on the
tape.
signals using the INPUT SELECT button, the
wide-screen information on the input signals will
be recorded regardless of this menu’s setting.