12.0 Care of the Boiler

20

© Baxi Heating UK Ltd 2010

12.1

Cleaning the Outer case

The painted panels should be wiped with a damp cloth and
then dried completely. DO NOT USE ABRASIVE
CLEANING AGENTS.

12.2

Maintenance

The appliance MUST be serviced annually by a Baxi authorised

engineer.

12.3

Condensate drain

The condensate drain, located at the bottom of the appliance,

must not be modified or blocked. Blockage will cause the

appliance to shut down.

12.4

Protection & Precaution

1. The appliance incorporates frost protection for itself only,

fitted as standard. If the system has a Programmable Room

Unit mounted in a cradle on a wall then the central heating

system will also be protected.

2. In cold weather, if you are going away, turn the appliance off

at the time switch ONLY. Leave the mains supply switched

ON.

3. If a system frost thermostat has been fitted (your installer

will be able to advise you), then to operate correctly and

protect your system, the gas and electricity must be left on and

the appliance set in the central heating mode.

4. The boiler incorporates an integral pump protection feature

which continually monitors the time since the pump last

operated. To prevent seizure, the pump will operate for

approximately 1 minute if it has not run in the last 24 hours.

12.5

Fault Indication

1. If a fault occurs on the boiler an error code may be shown

on the facia display.

12.6

In an Emergency

If a gas leak occurs or is suspected, the boiler can be
isolated at the inlet valves as follows;

1. Using a suitable open ended spanner, turn the square
nut on the gas tap through 90° (

1

/

4

turn) in a clockwise

direction to isolate the gas supply at the boiler.

2. Call your Installer or Service Engineer as soon as
possible.

Gas Service Cock

View from under appliance

Off Position

On Position

Test Nipple

If you smell gas

Do not operate light switches
Do not operate any electrical equipment
Do not use a telephone in the hazardous area
Extinguish any naked flame and do not smoke
Open windows and doors in the hazardous area
Turn off the gas supply at the meter
Warn any other occupants and vacate the premises
Telephone the National Gas Emergency Service on:-
0800 111 999

Faulty boiler

If it is known or suspected that a fault exists
on the boiler, it must not be used until the fault
has been corrected by a competent person.

Warning !