10.0 Clearances

17

© Baxi Heating UK Ltd 2010

200mm Min

950mm

450mm

300mm Min

5mm Min

5mm Min

450mm Min

For Servicing

Purposes

In Operation

60mm Min

426mm

10.1

For your Safety

1. This appliance must have been installed in accordance
with the manufacturer’s instructions and the regulations
in force.

2. Any modification that may interfere with the normal
operation of the appliance without express written
permission from the manufacturer or his agent could
invalidate the appliance warranty. In GB this could also
infringe the Gas Safety (Installation and Use) Regulations.

3. Your boiler must not be operated without the casing
correctly fitted.

4. Do not interfere with any sealed components on this
boiler.

5. Take note of any warning labels on your boiler.

6. Your boiler should have the following minimum
clearances for Safety and Maintenance :-

Top

- 200mm

Bottom

- 200mm

Left side

- 5mm

Right Side

- 60mm

Front

- 5mm (In Operation)
- 450mm (For Servicing)

7. If your boiler is installed in a compartment, do not use
it for storage purposes. Do not obstruct any purpose
provided ventilation openings.

8. Flammable materials must not be stored in close
proximity to your boiler.

9. Avoid skin contact when your boiler is in operation, as
some surfaces may get hot e.g. pipework.

10. Ensure that the flue terminal, outside the house,
does not become damaged or obstructed, particularly
by foliage.

11. It is important that the condensate drain system is
not blocked, modified or damaged in any way as this
would affect the operation of your boiler. Your installer
should have insulated any exposed pipework.

GB - Heating Industry definition meaning England, Scotland,
Wales, Northern Ireland, Isle of Man and the Channel Isles