APPENDIX A
SPECIFICATIONS
A.1 CLOCKING MODES
Network (G.703)
A.2 DTE RATE
All 64k steps from 64 to 2048 kbps
A.3 DIAGNOSTICS
V52 compliant (511/511E) pattern generator and detector with error
injection mode. Remote Loopback (toward DSL line) and local loopback
(toward G.703 network) control by a single front panel switch
A.4 LED STATUS
The following LEDs are displayed on the front panel:
• DSL Link (Green Active) - DSL Link Active
• E1 Link (Green Active) - Valid G.703/G.704 connection
• LOS (Red Active) - E1 loss of framing
• NS (Red Active) - No signal DSL Link
• ER (Flashing Red) - CRC error during nor-mal operation, bit error dur-
ing pattern gen-eration test
• TM (Active Yellow) - Test Mode Enabled
A.5 CONFIGURATION
Externally accessible dip switches or SNMP managed through 1095RC
A.6 POWER
5 VDC from external desk top power supply, 90-260VAC, 50-60 Hz (Uni-
versal Input), 10W or -48 VDC
A.7 COMPLIANCE
FCC Part 15, CE, CTR12, CRTR13 Transmission Line: Single Twisted
Pair