APPENDIX A

SPECIFICATIONS

A.1 CLOCKING MODES

Network (G.703)

A.2 DTE RATE

All 64k steps from 64 to 2048 kbps

A.3 DIAGNOSTICS

V52 compliant (511/511E) pattern generator and detector with error
injection mode. Remote Loopback (toward DSL line) and local loopback
(toward G.703 network) control by a single front panel switch

A.4 LED STATUS

The following LEDs are displayed on the front panel:

• DSL Link (Green Active) - DSL Link Active

• E1 Link (Green Active) - Valid G.703/G.704 connection

• LOS (Red Active) - E1 loss of framing

• NS (Red Active) - No signal DSL Link

• ER (Flashing Red) - CRC error during nor-mal operation, bit error dur-

ing pattern gen-eration test

• TM (Active Yellow) - Test Mode Enabled

A.5 CONFIGURATION

Externally accessible dip switches or SNMP managed through 1095RC

A.6 POWER

5 VDC from external desk top power supply, 90-260VAC, 50-60 Hz (Uni-
versal Input), 10W or -48 VDC

A.7 COMPLIANCE

FCC Part 15, CE, CTR12, CRTR13 Transmission Line: Single Twisted
Pair