Pl an ni ng in st al la tio n, Canada – Lennox Hearth GRANDVIEW GV230 User Manual
Page 7
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 4
Figure 3
Pl
an
ni
ng
In
st
al
la
tio
n
Sa
fe
ty
a
nd
G
en
er
al
In
st
al
la
tio
n
Op
er
at
io
n
M
ai
nt
en
an
ce
Tr
ou
bl
es
ho
ot
in
g
Pa
rts
/
Ac
ce
ss
or
ie
s
Footnotes:
1- These dimensions to the stove body are for reference
only. Actual distances should be measured from the
stove’s flue collar.
2- Minimum noncombustible hearth pad dimensions.
3- Clearances to connector pipe shall be measured from
the flue collar of the stove.
4- Not applicable to alcove installations.
INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 AND 4
Pl
an
ni
ng
In
st
al
la
tio
n
Stove
Stove
Stove
Alcove
Floor
Protection
Floor
Protection
Floor
Protection
Combustible W
all
Combustible Wall
Combustible
Wall
Alcove Depth
48" (1219mm) MAX.
E
†
USA
E
†
USA
K
K
J
D
C
B
A L
H
I
T
F
F
G
G
M
I
U
Corner Installation
Alcove or Parallel Installation
Alcove or Parallel Installation
Elbow
Elbow
Figure 2
Top View
Side View
Top View
E
Canada
†
† See note 8
USA
- inches (millimeters)
PIPE
INSTALLATION
A (3) B (1) C (3) D (1) E (8) F (1,4) G(3,4) H (2)
I
(6)
J (2)
K (7)
L (5)
M
T (6)
U
Single Wall Residential-Vertical Vent
16 12-3/8
22 12-1/2
8 5-11/16 16 38-5/8
51
33
16
0
84
58-7/8
N/A
(406) (314) (559) (318) (200) (145) (406) (981) (1295)
(838)
(406)
(0) (2134) (1495)
N/A
Single Wall Residential-With Elbow
19 15-3/8
23 13-1/2
8
5-11/16 16 38-5/8
54
33
16
0
84
58-7/8
19
(483) (391) (584) (343) (200) (145) (406) (981) (1372)
(838)
(406)
(0) (2134) (1495)
N/A
Double Wall Residential or Mobile Home-Vertical Vent
10 6-3/8
20 10-1/2
8 4-11/16 15
38-5/8
45
33
16
0
84
57-1/2
N/A
(254) (162) (508) (267) (200) (119) (381) (981) (1143)
(838)
(406)
(0) (2134) (1461)
N/A
Double Wall Residential or Mobile Home-With Elbow
10
6-3/8
21 11-1/2
8
4-11/16 15
38-5/8
45
33
16
0
84
57-1/2
10
(254) (162) (533) (292) (200) (119) (381) (981) (1143)
(838)
(406)
(0) (2134) (1461)
N/A
Double Wall Alcove-Vertical Vent
13 9-3/8 22-1/2 13
8
N/A
N/A 38-5/8
48
33
16
0
72
N/A
N/A
(330) (238) (572) (330) (200)
N/A
N/A
(981) (1219)
(838)
(406)
(0) (1829)
N/A
N/A
CANADA
- inches (millimeters)
PIPE
INSTALLATION
A (3) B (1) C (3) D (1) E (8) F (1,4) G(3,4) H (2)
I
(6)
J (2)
K (7)
L (5)
M
T (6)
U
Single Wall Residential-Vertical Vent
16 12-3/8
22 12-1/2
8 5-11/16 16
49
53
41-1/8
18
8
84
58-7/8
N/A
(406) (314) (559) (318) (200) (145) (406) (1235) (1346) (1045) (450) (200) (2134) (1495)
N/A
Single Wall Residential-With Elbow
19 15-3/8
23
13-1/2
8
5-11/16 16
49
56
41-1/8
18
8
84
58-7/8
19
(483) (391) (584) (343) (200) (145) (406) (1235) (1422) (1045) (450) (200) (2134) (1495) (483)
Double Wall Residential or Mobile Home-Vertical Vent
10 6-5/16
20 10-1/2
8 4-11/16 15
47
47
41-1/8
18
8
84
57-1/2
N/A
(254) (160) (508) (267) (200) (119) (381) (1193) (1193) (1045) (450) (200) (2134) (1461)
N/A
Double Wall Residential or Mobile Home-With Elbow
10 6-5/16
21 11-9/16
8
4-11/16 15
47
47
41-1/8
18
8
84
57-1/2
10
(254) (160) (533) (293) (200) (119) (381) (1193) (1193) (1045) (450) (200) (2134) (1461) (254)
Double Wall Alcove-Vertical Vent
13 9-3/8 22-1/2 13-1/16
8
N/A
N/A
49
50
41-1/8
18
8
72
N/A
N/A
(330) (238) (572) (331) (200)
N/A
N/A
(1235) (1270) (1045) (450) (200) (1829)
N/A
N/A
5- In corner applications, when installed at minimum
back wall clearances, the required floor protection
is dimensioned off the back plane of the stove,
therefore the floor protection required off the
back corners (at a 45 degree angle) only needs to
extend to the wall. This situation will only occur in
CANADA installations.
6- Reference dimension only, to assist in planning the
installation.
7- Measured from front of floor protection to the front of
firebox.
8- USA=8” (200mm) from door opening, Canada=8”
(200mm) from sides and back of unit.