B-10
B-10
V350-PRO
AUXILIARY POWER
• 115VAC, 42VAC and 24VAC power is available from
the 14-pin MS-style connector. The Construction
model of the Invertec V350-Pro does not have the
14-pin MS-style connector) These supplies are
intended to supply power for auxiliary equipment like
wire feeders and the TIG Module.
• 115VAC supply is rated at 2 amps and is protected by a 3.5
amp breaker.
• 42 VAC supply is rated at 5.5 amps and is protected
by a 6 amp breaker.
• 24 VAC supply is rated at 5.5 amps and is protected
by a 6 amp breaker.
LIMITATIONS
• The V350-Pro is not recommended for processes
other than those listed.
• The V350-Pro can only be used with the recom-
mended equipment and options.
RECOMMENDED PROCESSES
Properly equipped, the Invertec V350-Pro supports
GMAW-P, FCAW, SMAW, GTAW and CAC-A
processes for a variety of materials, including mild
steel, stainless steel, cored wires, and aluminum.