Gas Line Installation
This stove must be connected to the gas line in accordance
with local codes and/or the National Fuel Gas Code, ANSI
Z223.1 (In Canada, the current CAN/CSA B149.1 installa-
tion code).
The gas line screws into the gas valve at the back of the stove
5” in from the right side of the stove and 4 3/16” up from
the base of the unit. After connecting the gas line, all joints
in the line and connections at the valve should be checked
for leaks.. After connecting the gas line, all joints in the line
and connections at the valve should be checked for leaks
using a gas leak test solution.
g
as
p
ressure
r
equirements
A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS
APPLIANCES IS IMPROPER GAS PRESSURE!
The most important item to check during the initial
installation and the first thing to check when operating
problems occur is gas pressure! This appliance will
not function properly unless the required gas pressure
is supplied. See the table on this page for gas pressure
requirements.
Two pressure taps are provided on the stove’s valve to check
gas pressures. To access the taps remove the two socket
head screws to remove the valve control panel. The taps
are located above the on/off/pilot knob (see the diagram on
page 21). The right tap is the inlet (supply) pressure side.
To check inlet pressure (with the stove burning) insert a
small flat bladed screw driver into the tap and turn a half
turn counter-clockwise. Cover the tap with the line from a
manometer. Read the pressure. Close tap gently but securely
after completing the check. The manifold (outlet) tap is to
the left of the inlet tap. To check manifold pressure (with
the stove burning at the high burn setting) insert a small flat
bladed screwdriver into the tap and turn a half turn counter-
clockwise. Cover the tap with the line from the manometer
and check the pressure. Again close tap gently but securely
after completing the check. Check the taps for gas leaks with
a gas leak test solution (retighten if necessary).
lp
and
n
atural
g
as
s
upplies
:
Your Vintage™ gas stove is equipped from the factory for
use with natural gas only as specified on the Safety / Listing
label attached to the appliance. This appliance can only be
operated using propane gas (LP) if a certified fuel conver-
sion kit provided by Lennox Hearth Products is installed by
a qualified service technician.
Also check the orifice size on the label on the igniter bracket.
It must be the correct size for the fuel and altitude.
Do not run propane tank dry. Running the tank dry may
cause a hazardous condition due to pressure drop in
empty tank.
Solid fuel is NOT to be used with this unit.
Fuel
Type
Inlet Pressure
Manifold Pressure
Desired Minimum Maximum
On Hi
Fire
On Lo
Fire
Natural
Gas
7" WC
5" WC
10.5" WC .5" WC 1.8" WC
LP Gas
11" WC
11" WC
1" WC
10" WC .0” WC
If the pressure is not sufficient, make sure the gas supply line
is large enough, The supply regulator is properly adjusted,
and the total gas load for the residence does not exceed the
amount supplied.
The appliance and its individual shut off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/ psig.
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/ psig.