beautypg.com

Lennox Hearth VIS35 User Manual

Page 12

background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

v

ent

p

arts

l

ist

Direct vent pipe Security™ Secure Vent™ * may be used

with the Vintage™ gas stove. Please see the lists below

to verify the components available from each direct vent

pipe manufacturer. Snorkel terminations are available for

applications which may require vertical rise on the building

exterior. The components listed below come in a galvanized

finish. Most of the components are also available in a painted

black finish. Add a “B” to the end of the part number when

ordering if a black part is desired.

s

eCurity

™ s

eCure

v

ent

6-5/8”

x

4” p

ipe

Part Number

Description

SV4LC

6” Pipe Length

SV4L12

12” Pipe Length

SV4L24

24” Pipe Length

SV4L36

36” Pipe Length

SV4L48

48” Pipe Length

SV4LA

6” Pipe, Adjustable

SV4LA12

12” Pipe, Adjustable

SV4FA

Flashing, 1/12 to 6/12 Roof Pitch

SV4FB

Flashing, 7/12 to 12/12 Roof Pitch

SV4RSM

Wall Radiation Shield

SV4E46

45º Elbow

SV4E90

90º Elbow

SV4VS

Vinyl Shield Protector

SV4FC

Storm Collar

SV4CGV

Vertical Termination Cap

SV4BF

Firestop

SV4CHC

Horizontal Termination Cap

SV4STC36

Snorkel Termination Cap (36”)

SV4STC14

Snorkel Termination Cap (14”)

SV4BM

Wall Band

Simpson Dura-Vent GS 6-5/8”x 4” Pipe

Part Number

Description

908

6” Pipe Length

907

9” Pipe Length

906

12” Pipe Length

904

24” Pipe Length

903

36” Pipe Length

902

48” Pipe Length

911

11” to 14-5/8” Pipe, Adjustable

942

Wall Thimble

940

Rnd Support Box/Wall Thimble Cover

941

Cathedral Ceiling Support Box

943

Flashing, 0/12 to 6/12 Roof Pitch

943S

Flashing, 7/12 to 12/12 Roof Pitch

945

45º Elbow

990

90º Elbow

950

Vinyl Siding Standoff

953

Storm Collar

963

Ceiling Firestop

988

Wall Strap

981

Snorkel Termination (36”)

982

Snorkel Termination (14”)

984

Horizontal Termination Cap

985

Horizontal Termination Cap (High Wind)

980

Vertical Termination Cap

991

Vertical Termination Cap (High Wind)

h

orizontal

v

ent

i

nstallation

Venting terminals may not be recessed into a wall or

siding.

1. Set the unit in the desired location. Check whether or

not wall studs are in the way when the venting system is

attached. If wall studs are in the way, you may want to

adjust the location of the unit.

2. Any stove that is horizontally terminated and has a vertical

section of pipe off the top of the stove, that first section

of pipe must be a minimum of 18” long.

3. All horizontally terminated vent installations may only use

6-5/8”x 4” Security™ Secure Vent pipe*.

4. Assemble the desired combination of pipe and elbow(s)

to the appliance adapter with pipe seams facing down.

Offsetting the pipe seams as double seams in one place

will cause the outer pipe to take an oval shape.

5. When this pipe passes through a wall, a wall thimble

- Simpson #942 or Security™ #SV4RSM - is required.

The hole in the wall for the wall thimble should be 9-1/4”x

10-1/4”. If the wall being penetrated is constructed of non-

combustible material (i.e. masonry block or concrete), a

7” diameter hole is acceptable and a wall thimble is not

required.

6. Horizontal runs of vent pipe must be supported every 3

feet. Wall straps - Simpson #988 or Security™ #SV4BM

- are available for this purpose.

7. If the vent passes through a ceiling or floor, a firestop

- Simpson #963 or Security™ #SV4BF - is required.

8. Also note that venting terminals shall not be recessed

into a wall or siding. If installing the termination cap on

a wall covered with vinyl siding, a vinyl siding standoff

- Simpson #950 or Security™ #SV4VS - or furring strips

must be used to ensure that the termination cap is not

recessed into the siding.

9. The horizontal run of vent should have a 1/4” rise for every

12” of run toward the termination. Never allow the vent to

run downward. This could cause high temperatures and

may present the possibility of a fire.

10.If the wall being penetrated is constructed of noncom-

bustible material, such as masonry block or concrete,

an 7” diameter hole is acceptable and a wall thimble is

not required..

11. The location of the horizontal vent termination on an exte-

rior wall must meet all local and national building codes,

and must not be blocked or obstructed. For allowable

external vent termination locations (see page 16).

12. Allowable clearances from the vent pipe to combustible

materials must be maintained. See page 7 for these clear-

ances.

13. Do not locate the termination cap where it may be blocked

by shrubbery or snow.

* Other approved chimney brand is Simpson Dura-Vent DV-GS.