181
set timer
Syntax:
set timer
Description:
To set gvrp join time, leave time, and leaveall time for each port.
Argument:
Leave Time must equal double Join Time at least.
Possible value:
Example:
GSW-2496(gvrp)# set timer 2-8 25 80 2000
show config
Syntax:
show config
Description:
To display the gvrp configuration.
Argument:
None
Possible value:
None
Example:
GSW-2496(gvrp)# show config
GVRP state: Enable
Port Join Time Leave Time LeaveAll Time Applicant Registrar Restricted
---- --------- ---------- ------------- --------------- --------- ----------
1 20 60 1000 Normal Normal Disable
2 25 80 2000 Normal Normal Disable
3 25 80 2000 Normal Normal Disable
4 25 80 2000 Normal Normal Disable
5 25 80 2000 Normal Normal Disable
6 25 80 2000 Normal Normal Disable
7 25 80 2000 Normal Normal Disable
8 25 80 2000 Normal Normal Disable
:
:
23 20 60 1000 Normal Normal Disable
24 20 60 1000 Normal Normal Disable