Observing Boot Messages

A-2

INA Module Installation and Configuration Guide

Observing Boot Messages

If you are having difficulty booting the INA module and are unable to isolate the
problem by observing LED behavior, boot the INA module in console mode and check
the boot messages.

Follow these instructions to check boot messages:

1.

Attach a console.

See “Connect a Console (Optional)” on page 3-3.

No console login prompt is
displayed.

Terminal settings are
incorrect or a connection or
cable is inoperable.

• Verify terminal settings of 9600

baud, 8 data bits, 1 stop bit, a parity
of none, and software control
(XON/XOFF).

• Verify that DIP switch 1 is set to the

right.

• Verify that you have a working null

modem cable and that it is properly
connected at both ends. For cable
information see “Console Cable” on
page B-1.

Ethernet link LED is not lit
when connected to a
10BaseT Ethernet hub.

There is no link integrity.

Verify that you have a working
10BaseT cable properly connected to
the INA module and to the hub.

Network activity LED is
solidly lit.

Heavy traffic can cause the
network LED to blink so
rapidly that it appears to be
solidly lit.

However, if packets cannot
be passed, you might have
an incorrectly cabled
network.

Verify that the network cables are
correctly installed.

Network activity LED is not
lit.

If the INA module is not
receiving or sending traffic,
the network LED is not lit.

Verify that the network cables are
correctly installed.

An undefined difficulty
occurred at startup, but the
cause cannot be determined
from LED behavior.

Refer to the solution
column.

Try booting in console mode, and
observe the boot messages. See
“Observing Boot Messages” on page
A-2.
If the boot messages do not
suggest a solution, record the
information and contact Lucent
technical support.

Table A-1

Hardware Problems and Solution (Continued)

LED Behavior

Possible Cause

Solution