beautypg.com

C4t4vm, Calculite, Hid downlight – Lightolier Calculite HID Downlight C4T4VM User Manual

Page 2: Job information type

background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609

Job Information

Type:

Calculite

®

HID Downlight

C4T4VM

Page 2 of 4

4½" Aperture, 2pc Vertical, T4 Medium Beam

ANGLE MEAN CP LUMENS

0

1595

5

1524

143

10

1345

15

1109

314

20

867

25

649

308

30

493

35

396

248

40

294

45

125

107

50

10

55

0

2

60

0

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS % LAMP %LUMINAIRE

0-30

764

44.96

68.13

0-40

1012

59.56

90.25

0-60

1121

66

100

0-90

1121

66

100

40-90

109

6.43

9.75

60-90

0

0

0

90-180

0

0

0

0-180

1121

66

100

20W T4 GE CMH Lamp, Lumen Rating = 1700 LMS, Aromat 20W Electronic Ballast CL Finish Trim

750

1500

1125

375

LUMINANCE SUMMARY CD. / SQ. M.

ANGLE MEAN CD/SQ M

45

17255

55

39

65

0

75

0

85

0

**EFFICIENCY = 66.0%**

CERTIFIED TEST REPORT NO. 2322FR, DATE: OCT 04, 2003

SC = .7

COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER DISTRIBUTION

ANGLE MEAN CP LUMENS

0

2306

5

2232

211

10

2064

15

1856

523

20

1601

25

1313

616

30

1095

35

902

551

40

609

45

243

216

50

20

55

3

6

60

0

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

39W T4 Philips CMH Lamp, Lumen Rating = 3300 LMS, Aromat 39W Electronic Ballast, CL Finish Trim

1250

2500

LUMINANCE SUMMARY CD. / SQ. M.

ANGLE MEAN CD/SQ M

45

33651

55

466

65

0

75

0

85

0

**EFFICIENCY = 64.3%**

CERTIFIED TEST REPORT NO. 2321FR, DATE: OCT 01, 2003

SC = .8

COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS % LAMP %LUMINAIRE

0-30

1349

40.9

63.6

0-40

1900

57.59

89.56

0-60

2121

64.3

100

0-90

2121

64.3

100

40-90

221

6.72

10.44

60-90

0

0

0

90-180

0

0

0

0-180

2121

64.3

100

ANGLE MEAN CP LUMENS

0

4707

5

4560

430

10

4188

15

3667

1032

20

3046

25

2445

1148

30

1987

35

1587

982

40

1090

45

444

390

50

38

55

3

10

60

0

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

70W T4 Philips CMH Lamp, Lumen Rating = 6400 LMS, Aromat 70W Electronic Ballast, CL Finish Trim

2250

4500

LUMINANCE SUMMARY CD. / SQ. M.

ANGLE MEAN CD/SQ M

45

61418

55

584

65

0

75

0

85

0

**EFFICIENCY = 62.4%**

CERTIFIED TEST REPORT NO. 2320FR, DATE: OCT 01, 2003

SC = .8

COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS % LAMP %LUMINAIRE

0-30

2610

40.79

65.39

0-40

3592

56.13

89.97

0-60

3992

62.38

100

0-90

3992

62.38

100

40-90

400

6.26

10.03

60-90

0

0

0

90-180

0

0

0

0-180

3992

62.38

100

375

750

1125

1500

625

1250

1875

2500

1125

2250

3375

4500

30°

60°

30°

60°

30°

60°

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.79

.79

.79

.79

.77

.77

.74

.74

.71

.71 .66

1

.76

.74

.73

.72

.73

.71

.70 .68 .68 .66 .63

2

.73

.70 .68 .66 .69 .65

.67 .64 .65 .63 .60

3

.70 .66 .64

.61 .65

.61 .64 .60 .62 .59

.57

4

.67 .63 .60 .58 .62

.57

.61

.57 .60 .56 .54

5 .64 .60 .56 .54 .59 .54 .58 .53

.57 .53

.51

6 .62

.57 .53

.51 .56

.51 .55 .50 .54 .50

.49

7 .59 .53 .50

.48 .53

.47

.52

.47

.51

.47

.46

8 .56

.51

.47

.45 .50

.45

.49 .44

.49 .44 .43

9 .53

.48 .44

.42

.47

.42

.47

.42

.46

.42

.41

10

.51

.45

.42 .39

.45 .39 .44 .39 .44 .39 .38

LUMINAIRE INPUT WATTS = 23

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.77

.77

.77

.77

.75

.75

.72

.72 .69 .69 .65

1

.74

.72

.71

.70

.71 .68 .68 .66 .66 .64

.61

2

.71 .68 .66 .64

.67 .63 .65 .62 .63 .60 .58

3 .68 .64

.61 .59 .63

.59 .62 .58 .60

.57 .55

4 .65 .60

.57 .55 .60 .54 .58 .54

.57 .53

.52

5 .62

.57 .53

.51 .56

.51 .55 .50 .54 .50

.49

6 .59 .54 .50

.48 .53

.48

.52

.47

.51

.47

.46

7 .56

.51

.47

.45 .50 .44

.49 .44

.48 .44 .43

8 .53

.47 .44

.42

.47

.41

.46

.41

.46

.41

.40

9 .50

.45

.41 .39 .44 .39 .44 .38 .43 .38 .37

10

.48

.42 .38 .36

.42 .36

.41 .36

.41 .36 .35

LUMINAIRE INPUT WATTS = 44

Coefficients of Utilization

Ceiling

80%

70%

50%

30%

Wall

70

50

30

10

50

10

50

10

50

10

0

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

0

.74

.74

.74

.74

.73

.73

.70

.70

.67

.67 .63

1

.71

.70 .69

.67 .69 .66 .66 .64 .64 .62 .59

2 .68 .66 .64 .62 .65

.61 .63 .60

.61 .59 .56

3 .66 .62 .59

.57

.61

.57 .60 .56 .58 .55 .53

4 .63

.59 .56 .54 .58 .53

.57 .53 .56

.52

.51

5 .60 .56

.52 .50 .55 .50 .54

.49 .53

.49

.48

6

.57 .53

.49

.47

.52

.47

.51

.46 .50

.46

.45

7 .55

.49

.46 .44

.49 .44

.48

.43

.47 .43

.42

8

.52

.47 .43

.41

.46

.41

.46

.41

.45

.40 .39

9

.49 .44

.41 .38 .44 .38 .43 .38

.42 .38 .37

10

.47

.41 .38 .36

.41 .36

.41 .36

.40 .35 .34

LUMINAIRE INPUT WATTS = 78