Table 3D (continued from previous page) Troubleshooting Chart - Fault Messages Displayed on Pool Heater
Interface

F

FA

AU

UL

LT

T

D

DE

ES

SC

CR

RIIP

PT

TIIO

ON

N

C

CO

OR

RR

RE

EC

CT

TIIV

VE

E A

AC

CT

TIIO

ON

N

Pool Standby /

Low Water Flow

The pool heater has a call for heat, but
there is insufficient water flow.

• Verify that the system is full of water and that all air

has been properly purged from the system.

• Verify that the pool heater is piped properly into the

heating system. Reference Section 7 - Water
Connections in the EnergyRite Installation and
Operation Manual for the proper piping methods for
the pool heater.

• Replace the switch.

Outlet Sensor

Open

The control does not sense the presence
of an outlet sensor.

• Ensure proper wiring of the outlet sensor.

• Replace the sensor.

• Replace the main control board.

Inlet Sensor Open

The control does not sense the presence
of an inlet sensor.

• Ensure proper wiring of the inlet sensor.

• Replace the sensor.

• Replace the main control board.

Outlet Temp

Exceeded

The outlet temperature has exceeded the
maximum allowable outlet temperature.

• Verify that the system is full of water and that all air

has been properly purged from the system.

• Verify that the pool heater is piped properly into

the heating system. Reference Section 7 - Water
Connections in the EnergyRite Installation and
Operation Manual for the proper piping methods
for the pool heater.

• Measure the resistance of the sensors and

compare the resistance to Table 3B on page 23 of
this manual.

• Replace the sensor if necessary.

Lockout / Low

Water Flow

The pool heater sensed low water pressure
while the pool heater was running.

• Verify that the system is full of water and that all air

has been properly purged from the system.

• Verify that the pool heater is piped properly into

the heating system. Reference Section 7 - Water
Connections in the EnergyRite Installation and
Operation Manual for the proper piping methods
for the pool heater.

Button

Malfunction

One of the buttons has malfunctioned.

• Replace the board.