beautypg.com

Troubleshooting & repair, Power board test (cont.) – Lincoln Electric INVERTEC V300-PRO SVM105-B User Manual

Page 78

background image

V300-PRO

TROUBLESHOOTING & REPAIR

.

TEST PROCEDURE

NOTE: Perform Test A before disassembling the unit

Test A

1.

Turn main power OFF.

2.

Position yourself at Switch Board area of the
machine (near Case Back) so as to hear the oper-
ation of the control relays.

3.

Turn main power ON.

4.

Listen for control relays to operate (audible click of
contacts closing) after about a 5-second delay.

a. If audible click of control relay contacts closing

is heard, Power Board is probably OK.

b. If audible click of control relay contacts closing

is not heard, Power Board could be faulty. Go
to Test B.

NOTE: If the relays energize but there is still a
suspicion that the Power Board is faulty, go on to
Test B.

F-48

F-48

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

POWER BOARD TEST (cont.)

Test B

1.

Turn main power OFF.

2.

Remove wrap-around cover.

3.

Perform Input Filter Capacitor Discharge proce-
dure.

4.

Detach Control Panel by removing the four mount-
ing screws. Move the panel to the left to gain
access to the Power Board.

5.

Turn main power ON.

FIGURE F.22 - REMOVING CONTROLPANEL