TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Perform Input Filter Capacitor Discharge

Procedure detailed in this section.

2. Remove front panel from machine to access Control

Board.

3. Arrange wires so there is ample room to work on

the board.

4. Turn main power ON.

5. Test for 15 VDC between leads 302 and 275D.

a.

If 15 VDC is present, test is OK. Go to step 6.

b.

If 15 VDC is not present, check Power Board
and leads 302 and 275D for continuity and wire
breakage.

F-36

F-36

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

OVERCURRENT PROTECTION CURRENT TRIGGER TEST (cont.)

FIGURE F.12 - GETTING ACCESS TO CONTROL BOARD

G2527

CONTROL

302

275D

J5

J1

J2

J4

J3

FIGURE F.13 - CONTROL BOARD TEST POINTS