beautypg.com

Troubleshooting & repair – Lincoln Electric INVERTEC SVM101-B User Manual

Page 69

background image

V300-I

TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Turn main power OFF.

2. Perform Input Filter Capacitor Discharge procedure

detailed in Maintenance section.

3. Detach the following PC boards so you can gain

access to and have ample room to perform the
tests: (Do not disconnect from wiring harness.)

Control Board

Protection Board

Power Board

NOTE: Do not disconnect any wires. The machine
must be functional to perform tests.

4. Arrange the PC boards and wiring so you can easi-

ly perform the tests.

NOTE: Do not allow live connections to touch each
other.

5. Turn main power ON.

6. Move the Output Terminal Switch S4 to the ON posi-

tion (closed).

F-39