beautypg.com

3 operation example, 6 operational examples of aprs – Kenwood TH-D72A/E User Manual

Page 54

background image

6 OPERATIONAL EXAMPLES OF APRS

46

CONTENTS

TH-D72A/E

Figure 6-5 Speed vs Turn Threshold

Here are the TH-D72A/E default configurations for position beacon transmissions using the
SmartBeaconing configuration as shown below.

Table 6-7 SmartBeaconing Configuration Values

Note: If SmartBeaconing does not result in appropriate beacon transmissions, then you must re-configure individual parameters

so as to more closely match driving conditions.

6.1.5.3 Operation Example

Menu Item

Configured Value

LOW SPEED

5

HIGH SPEED

70

SLOW RATE

30 minutes

FAST RATE

120 seconds

TURN ANGLE

28°

TURN SLOPE

26 (x10°/speed)

TURN TIME

30 seconds

140

120

100

80

60

40

20

10

0

20

30

40

50

60

70

80

Speed

Speed vs Turn Threshold

T

u

rn Threshold

(degrees)

This manual is related to the following products: