beautypg.com

Kodak E User Manual

Page 42

background image

SERVICE MANUAL

42

30APR96 – SM4530-1

Auto Focus System

• After the initial focus adjustment, the auto-focus system will

adjust for the difference in the slide position from slide to
slide. This focus adjustment will occur within 1 second after
the slide is inserted into the GATE.

• The focus adjustment variation should not change from the

focus and reverse specifications by more than 3 times the
focus and reverse specifications.

Reliability

The projector can operate for 2000 hours or 2,000,000 cycles.
The projector has a MTBF (mean time between failures) of 7500
operation hours.

Maintenance

Preventive maintenance by a qualified service person is
recommended every 1500 hours of operation, or after 1 year.

Warranty

See the owner’s manual.

7-PIN REMOTE CONTROL
(See illustration below.)

• PIN 1 - Black, REMOTE FOCUS

• PIN 2 - Green, FORWARD TRAY CYCLE

• PIN 3 - Orange, REVERSE TRAY CYCLE

• PIN 4 - Brown, RACK SOLENOID

• PIN 5 - Yellow, COMMON

• PIN 6 - Brown, LAMP CONTROL

• PIN 6 - White, LAMP CONTROL

9-PIN SPECIAL APPLICATIONS
(See illustration below.)

• PINS 1 and 3 - ZERO POSITION SWITCH

• PINS 4 and 5 - SHUTTER SWITCH

• PINS 7 and 8 - LOW VOLTAGE SUPPLY, 25.5 V AC, 500

mA, 1/2 Amp Maximum

• PINS 6 and 8 - FORWARD TRAY CYCLE

• PINS 2 and 8 - REVERSE TRAY CYCLE and SHELL PLUG

GROUND

Item

Description

1

2

3

4

5

6

7

A100_0023AA

Y

W

N

O

G

N

K

7-PIN PLUG

A100_0023ACA

24 V AC

24 V AC

24 V AC

0 V AC

Common

Unloaded

82 V AC

1

2

3

4

5

6

7

8

A100_0022AA

SPECIAL APPLICATIONS PLUG

A100_0022ACA