background image

Replacements and Installations

SM4530-1 – 30APR96

15

Replacing the CAM STACK ASSEMBLY and CYCLE LEVER ASSEMBLY

Warning

Dangerous Voltage

[1] Disconnect the main power.

[2] Do the replacement procedure for the MECHANISM ASSEMBLY.

[3] Remove the INDEXER LEVER ASSEMBLY from the TOP PLATE of the MECHANISM ASSEMBLY.

[4] Remove the

Torx SCREW (on N.P. models) (or Hex SCREW on Painted Models) from the WORM PULLEY

ASSEMBLY.

[5] Remove the WORM PULLEY ASSEMBLY.

[6] Remove the DIRECTION LEVER LINK from the DIRECTION LEVER.

[7] Remove the DIRECTION LEVER SPRING from the DIRECTION LEVER.

[8] Disconnect the LIFT LEVER SPRING from LIFT LEVER on the TOP PLATE of the MECHANISM ASSEMBLY.

[9] Remove the RETARD SPRING.

[10] Remove the 7

Torx SCREWS (on N.P. models) (or Hex SCREWS on Painted Models) from the TOP PLATE of

the MECHANISM ASSEMBLY.

[11] Remove the TOP PLATE.

A008_0173HA

A008_0173HCA

SPRING

RETARD

STYLE 2

BEARING

E-RING

SPRING

RETARD

STYLE 1

SHAFT

LIFT LEVER

LIFT LEVER

BEARING

E-RING

NUT

CAM STACK ASSEMBLY