Adjusting the indexer lever assembly, Adjustment specification – Kodak E User Manual
Page 27
Adjustments
SM4530-1 – 30APR96
27
Adjustment Specification
This adjustment adjusts the strobe and timing of the INDEXER LEVER. Use TL-3000. The gate edge of the black
plastic of the INDEXER LEVER should be between the 2 holes at position 2.
Adjusting the INDEXER LEVER ASSEMBLY
Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the removal for the MECHANISM ASSEMBLY.
[3] Place the MECHANISM ASSEMBLY on the MECHANISM RUNNING FIXTURE TL-3000.
[4] Check the alignment of the INDEXER LEVER with the hole in the TOP PLATE ASSEMBLY at Position 1.
[5] Bend the INDEXER LEVER to the correct position.
[6] Check the travel of the INDEXER LEVER in the FORWARD position. When the INDEXER LEVER moves in
the FORWARD position, the gate edge of the black plastic should be between the 2 holes at Position 2.
[7] Bend the INDEXER LEVER until you reach the correct position.
Adjustment Specification
Use TL-3000 MECHANISM RUNNING FIXTURE. Use TL-3001 to measure the height of the SLIDE LIFT LEVER.
The LEVER should make contact with the low surface of TL-3001. The LEVER should not make contact with the
high surface of TL-3001.
position 1
position 2
A091_0008HA
MECHANISM
RUNNING FIXTURE
MECHANISM
ASSEMBLY
TOP PLATE
Bend
here.
A091_0008HCA