The shutter blades can be opened automatically by turning the three set-
up switches on the dissolve interface box to the ON position. Remember
to return these three switches to the OFF position to permit the dissolve
equipment to operate the shutter during your multimedia show.
Connect the dissolve equipment (AVL/Dataton/etc.) to the dissolve
interface unit. The dissolve interface will appear as a simulated projector
to the dissolve controller while it converts the signals from the dissolve
controller to operate the Xenon projector dissolve mechanism.
VR-1 Dissolve Shutter
Adjuster (Open)
VR-2 Dissolve Shutter
Adjuster (Close)
Dissolve Interface
Connector Terminal
(For the dissolve module of the 560DM/750DM projector.) Plug in the
AVL Dove X2 or Dataton PAX Dissolve Controller, as well as the Navitar
Dissolve Interface unit.
Adjusting Dissolve
Shutter Open/Close
Dissolve Shutter
Manual Knob
Units with Dissolve Module & Dissolve Interface
22
Screws
Dissolve Interface
Connector Terminal
VR-2 Dissolve Shutter
Adjuster (Closed)
VR-1 Dissolve Shutter
Adjuster (Open)
Dissolve Shutter
Manual Knob
8 mm
8 mm
6 mm
6 mm