SAT measurement
27
Example for a USER entry
You wish to check the EXR 22 KATHREIN matrix. The instruction set for
the EXR 22 matrix is E0 00 24 (LNB High) and E0 00 20 (LNB Low).
Calling up DiSEqC™:
Press [2ndF] [SAT-CTRL]
Press [0] to call up USER entry.
SAT-CTRL menu
You can now enter the indvidual code words by pressing [0] to [9] and
[./S]. Press [ENTER] to send the command. „>“ signalises the successful
sending of the command.
DiSEqC™ menu
The instruction set to trigger the EXR 22 KATHREIN matrix has been
entered and sent.
DiSEqC™ menu
Note
Please find the DiSEqC™ instruction sets for KATHREIN matrices, Types
EXR 20 and EXR 22 and for the 9xx production run in the technical
appendix.
Framing Byte Menu
HEX
Byte
description
E0
Command from master, nonrecurring transmission
E1
Command from master, recurrent transmission
E2
Command from master, response anticipated, first transmission
E3
Command from master, response anticipated, recurrent
transmission
E4
Response from slave, „OK“, no errors recognised
E5
Response from slave, command not supported by slave
E6
Response from slave, parity error recognised
E7
Response from slave, command not identified
DiSEqC-
DiSEqC-Framing
E ■
DiSEqC-COMMAND
E0 00 24 >
✐
☞