beautypg.com

6 operator messages, 6operator messages – Kodak 9500 User Manual

Page 54

background image

A-61092 September 1999

6-1

6

Operator Messages

This chapter outlines the actions that should be taken by the user and
system administrator when an operator message appears in the status
display.

If a message appears in the status display that is within the ranges
E000-E299 or E500-E599, you should take the action indicated in the
table(s) in this chapter.

IMPORTANT:

Never power down the machine without first contacting
your system administrator.

If a message appears in the status display that is within the ranges
E300-E499 or E600-E999, contact your system administrator.

The following action(s) should be taken:

Determine whether or not the error can be addressed from the host

system.

If the error cannot be addressed from the host system, attempt to

clear the error by taking the action indicated in the table(s) in this
chapter.

If the prescribed action(s) does not clear the error, initiate a

controlled power-down sequence:

Wait for all information currently held in the buffer to be

transferred to the host system.

Turn off the scanner transport using the side panel switch.

Turn off the scanner power using the main power switch.

Wait 10 to 30 seconds.

Turn on the scanner power using the main power switch.

Turn on the scanner transport using the side panel switch.

If the error condition is not cleared using the controlled power-down

sequence, contact service.