6 operator messages, 6operator messages – Kodak 9500 User Manual
Page 54
A-61092 September 1999
6-1
6
Operator Messages
This chapter outlines the actions that should be taken by the user and
system administrator when an operator message appears in the status
display.
If a message appears in the status display that is within the ranges
E000-E299 or E500-E599, you should take the action indicated in the
table(s) in this chapter.
IMPORTANT:
Never power down the machine without first contacting
your system administrator.
If a message appears in the status display that is within the ranges
E300-E499 or E600-E999, contact your system administrator.
The following action(s) should be taken:
•
Determine whether or not the error can be addressed from the host
system.
•
If the error cannot be addressed from the host system, attempt to
clear the error by taking the action indicated in the table(s) in this
chapter.
•
If the prescribed action(s) does not clear the error, initiate a
controlled power-down sequence:
−
Wait for all information currently held in the buffer to be
transferred to the host system.
−
Turn off the scanner transport using the side panel switch.
−
Turn off the scanner power using the main power switch.
−
Wait 10 to 30 seconds.
−
Turn on the scanner power using the main power switch.
−
Turn on the scanner transport using the side panel switch.
•
If the error condition is not cleared using the controlled power-down
sequence, contact service.