beautypg.com

Camera warnings – Konica Minolta APS Camera User Manual

Page 55

background image

Use higher speed film, increase the brightness, cancel
spot metering.

107

106

MODE

DISPLAY

CAUSE

P

A

S

Spot

ACTION

Shutter speed and

aperture blink

2000, 125, or 30” blinks

Maximum or Minimum

aperture blinks

blinks

LEnS appears

FILM appears

Light level is beyond the range of
available shutter speeds and
apertures.

Required aperture is beyond the
range of the lens.

Light level is below the camera’s
minimum metering range.

Lens is not attached, or is
attached improperly.

Film is not loaded.

Required shutter speed is beyond
the range of the camera.

In bright light, attach a neutral density (ND) filter, use film
with lower film speed, or reduce the overall brightness of
your surroundings. In low-light, use flash or another light
source to increase the brightness of your surroundings.

Select a larger/smaller aperture until the display stops
blinking.

Select a faster/slower shutter speed until the display
stops blinking.

Attach the lens, or disconnect and reattach the lens.
If the camera is attached to a microscope or telescope;
contact a Minolta Service Facility for information.

Load film.

Err appears

Camera malfunction

Turn the camera off, then remove and reinsert the
batteries. If normal operation does not resume or the
camera malfunctions repeatedly, contact an authorized
Minolta Service Facility.

PAGE

82-83

20

and blink

Date memory can be lost when
the batteries are changed.

Reset the date and time.

CAMERA WARNINGS

All

All

All

All