Adjustment – Kenwood TK-480 User Manual
Page 38

37
ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
TK-480/481
9. DQT BAL
1) SYS – GRP : 4 – ✽
Power meter Panel
ANT
Panel
Encoder Make the demodu-
adjustment
Select
BAL ✽ ✽ ✽
Deviation
knob
lation waves into
in tuning mode.
meter
square waves.
Deviation meter filter setting
Oscilloscope
LPF : 3kHz
HPF : OFF
AG
PTT : ON
AF VTVM
10. MAX DEV
1) SYS – GRP : 4 – ✽
Universal
TK-480 : 3.8kHz
±
50Hz
adjustment
Select
MAX ✽ ✽ ✽
TK-481 : 1.75kHz
in tuning mode.
(According to the
AG : 1kHz/150mV
larger +, –.)
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
Adjustment item
L MAX ✽ ✽ ✽
→
C MAX ✽ ✽ ✽
→
H MAX ✽ ✽ ✽
PTT : ON
11. T/A MAX
1) SYS – GRP : 4 – ✽
DEV
Select
TMAX ✽ ✽ ✽
adjustment
in tuning mode.
AG : 1kHz/150mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
Adjustment item
L TMAX ✽ ✽ ✽
→
C TMAX ✽ ✽ ✽
→
H TMAX ✽ ✽ ✽
PTT : ON
12. NPSPAC
1) SYS – GRP : 10 – ✽
TK-480 : 2.9kHz
±
50Hz
MAX DEV
Select
NMAX ✽ ✽ ✽
(According to the
adjustment
in tuning mode.
larger +, –.)
AG : 1kHz/150mV
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
Adjustment item
L NMAX ✽ ✽ ✽
→
C NMAX ✽ ✽ ✽
→
H NMAX ✽ ✽ ✽
PTT : ON
13. MIC
1) SYS – GRP : 4 – 1
Check
TK-480 : 2.2~3.6kHz
sensitivity
AG : 1kHz/15mV (TK-480)
TK-481 : 0.6~1.0kHz
check
AG : 1kHz/8mV (TK-481)
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON
14. T/A MIC
1) SYS – GRP : 4 – 1
sensitivity
TA mode : ON
check
(Press [A] key, then [C] key)
AG : 1kHz/15mV (TK-480)
AG : 1kHz/8mV (TK-481)
Deviation meter filter setting
LPF : 15kHz
HPF : OFF
PTT : ON