beautypg.com

Adjustment – Kenwood TK-480 User Manual

Page 38

background image

37

ADJUSTMENT

Measurement

Test-

equipment

Unit

Terminal

Adjustment

Unit

Parts

Method

Specifications/Remarks

Condition

Item

TK-480/481

9. DQT BAL

1) SYS – GRP : 4 – ✽

Power meter Panel

ANT

Panel

Encoder Make the demodu-

adjustment

Select

BAL ✽ ✽ ✽

Deviation

knob

lation waves into

in tuning mode.

meter

square waves.

Deviation meter filter setting

Oscilloscope

LPF : 3kHz
HPF : OFF

AG

PTT : ON

AF VTVM

10. MAX DEV

1) SYS – GRP : 4 – ✽

Universal

TK-480 : 3.8kHz

±

50Hz

adjustment

Select

MAX ✽ ✽ ✽

TK-481 : 1.75kHz

in tuning mode.

(According to the

AG : 1kHz/150mV

larger +, –.)

Deviation meter filter setting

LPF : 15kHz
HPF : OFF

Adjustment item

L MAX ✽ ✽ ✽

C MAX ✽ ✽ ✽

H MAX ✽ ✽ ✽

PTT : ON

11. T/A MAX

1) SYS – GRP : 4 – ✽

DEV

Select

TMAX ✽ ✽ ✽

adjustment

in tuning mode.

AG : 1kHz/150mV
Deviation meter filter setting

LPF : 15kHz
HPF : OFF

Adjustment item

L TMAX ✽ ✽ ✽

C TMAX ✽ ✽ ✽

H TMAX ✽ ✽ ✽

PTT : ON

12. NPSPAC

1) SYS – GRP : 10 – ✽

TK-480 : 2.9kHz

±

50Hz

MAX DEV

Select

NMAX ✽ ✽ ✽

(According to the

adjustment

in tuning mode.

larger +, –.)

AG : 1kHz/150mV
Deviation meter filter setting

LPF : 15kHz
HPF : OFF

Adjustment item

L NMAX ✽ ✽ ✽

C NMAX ✽ ✽ ✽

H NMAX ✽ ✽ ✽

PTT : ON

13. MIC

1) SYS – GRP : 4 – 1

Check

TK-480 : 2.2~3.6kHz

sensitivity

AG : 1kHz/15mV (TK-480)

TK-481 : 0.6~1.0kHz

check

AG : 1kHz/8mV (TK-481)
Deviation meter filter setting

LPF : 15kHz
HPF : OFF

PTT : ON

14. T/A MIC

1) SYS – GRP : 4 – 1

sensitivity

TA mode : ON

check

(Press [A] key, then [C] key)

AG : 1kHz/15mV (TK-480)
AG : 1kHz/8mV (TK-481)
Deviation meter filter setting

LPF : 15kHz
HPF : OFF

PTT : ON