beautypg.com

Adjustment, Test equipment required for alignment – Kenwood TK-480 User Manual

Page 33

background image

32

TK-480/481

ADJUSTMENT

Test Equipment Required for Alignment

Test Equipment

Major Specifications

1. Standard Signal Generator

Frequency Range

800 to 950MHz

(SSG)

Modulation

Frequency modulation and external modulation

Output

0.1

µ

V to greater than 1mV

2. Power Meter

Input Impedance

50

Operation Frequency

800 to 950MHz or more

Measurement Capability

Vicinity of 10W

3. Deviation Meter

Frequency Range

800 to 950MHz

4. Digital Volt Meter

Measuring Range

10mV to 10V DC

(DVM)

Input Impedance

High input impedance for minimum circuit loading

5. Oscilloscope

DC through 30MHz

6. High Sensitivity

Frequency Range

10Hz to 1000MHz

Frequency Counter

Frequency Stability

0.2ppm or less

7. Ammeter

5A

8. AF Volt Meter

Frequency Range

50Hz to 10kHz

(AF VTVM)

Voltage Range

1mV to 10V

9. Audio Generator (AG)

Frequency Range

50Hz to 5kHz or more

Output

0 to 1V

10. Distortion Meter

Capability

3% or less at 1kHz

Input Level

50mV to 10Vrms

11. Voltmeter

Measuring Range

10mV to 10V DC or less

Input Impedance

50k

/V or greater

12. 16

Dummy Load

Approx. 16

, 3W

13. Regulated Power Supply

5V to 10V, approx. 5A
Useful if ammeter requipped

The following parts are required for adjustment

1. Antenna connector adapter

The antenna connector of this radio uses an SMA termi-

nal.

Use an antenna connector adapter [SMA(f) – BNC(f) or

SMA(f) – N(f)] for adjustment. (The adapter is not provided
as an option, so buy a commercially-available one.)

Note

When the antenna connector adapter touches the knob,

draw out the knob to mount the connector.

2. Universal connector

Use the interface cable (KPG-36) for PC tuning or the lead

wire with plug (E30-3287-18) and screw (N08-0535-08) for
panel tuning. Connct the plug to the universal connector of
the radio and tighten the screw.

The lead wire with plug (E30-3287-18) and screw (N08-

0535-08) terminals are as follows. Numbers are universal
connector terminal numbers.

Caution

1. When connecting the plug to the universal connector of

the radio, a short circuit may occur. To prevent this, be
sure to turn the radio POWER switch off.

2. Since the RX AF output is a BTL output, there is a DC

component. Isolate this with a capacitor or transformer
as shown in the figure.

3. Do not connct an instrument between red or black and

GND.

• Universal connector

1: SSW

3: SP–

5: EMC

7: PTT

9: NC

11: 5M

13: RXD

2: SP+

4: MSW

6: ME

8: PF

10: E

12: TXD

14: NC