If a compare error is found in the check sequence from PASS1 to
PASS6, error print (error code E1) is performed. If there is no error
found to the end of the last address, the operation is completed
normally.
Then the following address check is performed. " " shows a valid
address, and "
✕
" shows an invalid address.
In case of an error, error code E2 is printed.
Check Address
JOB#201(ER-03RA)
200000H
200001H
200002H
200004H
200008H
200010H
200020H
200040H
200080H
200100H
200200H
200400H
200800H
201000H
202000H
204000H
208000H
210000H
220000H
240000H
260000H
3) Check the following items.
Check the termination print.
4) Test termination
The test terminates after printing the termination printout.
Termination print
E01---
200
(data check error)
E02---
200
(address check error)
200
(normal end)
: Error address
[15] RS-232 loop back test
Connect the loop back connector(UKOG-6705RCZZ) to RS232 con-
nector.
1) Key operation
2) Functional description
Control signal check
OUT PUT
INPUT
/ER
/RS
/DR
/CI
/CD
/CS
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
Data communication check
Perform 256-byte branch loop back test between SD and RD.
DATA: $00 - $FF
BAUD RATE: 9600 BPS
Display:
4) Test termination
This check is terminated automatically.
The test terminates with the test and message printed
XX: Error code
E1
ER-DR error
E2
ER-CI error
E3
RS-CD error
E4
RS-CS error
E5
SD-RD error (DATA error)
E6
SD-RD error (DATA error/Flaming error)
2
0
7-SEGMENT DISPLAY:
0
500
CA/AT
5 0 0
Normal end
Error
NG
RS TEST
ER XX
RS TEST
OK