Calibrating.Fence.Pointer

Your new bandsaw is equipped with a fence measurement

system that includes a fence pointer, which must be cali-

brated when the bandsaw is first set up.

To.calibrate.the.pointer,.do.these.steps:

1.. If the fence is mounted on the right-hand side of the

blade, remove it and re-install it on the left-hand

side of the blade.

2. Place the fence flush against the bandsaw blade (see

Figure.40).

3. Loosen the pointer adjustment screw (Figure.41),

and set the pointer in line with "0" and the measure-

ment scale on the table.

4. Tighten the pointer adjustment screw.

Figure 40. Example of fence flush with

blade.

Calibrating.Miter.Gauge

The miter gauge needs to be calibrated to the blade when

it is first mounted in the miter slot.

To.calibrate.the.miter.gauge,.do.these.steps:

1. Place one edge of a machinist's square against the

face of the miter gauge and place the other against

the blade face, as shown in

Figure 42.

2. Loosen the lock knob on the miter gauge and adjust

the gauge flush with the edge of the square.

3. Tighten the lock knob, and verify the setting.

Note: Sometimes the tightening procedure can

affect the adjustment.

4. Loosen the screw that secures the angle pointer and

adjust the pointer to the 0˚ mark on the scale.

5. Retighten the screw that secures the angle pointer.

Figure.41. Fence pointer adjustment

screw.

Figure.42. Example of squaring miter

gauge to blade.

Angle Pointer

Screw

Lock

Knob