Electrical

Installation must comply with all applicable electrical codes.

The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit,
servicing only this appliance is required. A ground fault cir-
cuit interrupter (GFCI) is not recommended and may cause
interruption of operation.

IMPORTANT NOTE:

The electrical outlet must be placed so

the grounding prong is to the right of the thinner blades.
The outlet must be flush with the back wall.

ELECTRICAL REQUIREMENTS

Power Supply

115 V AC, 60 Hz

Circuit Breaker

15 amp

Receptacle

3-prong grounding-type

WARNING

Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.

FRONT VIEW

15

1

/

2

"

(394)

3"

(76)

2"

(51)

LEFT SIDE

OF OPENING


Electrical supply location.

Preparation

To operate properly, the door must open a minimum of 90°.
Use a minimum 3"

(76)

filler in corner installations to assure

a 90° door opening.

Uncrate the unit and inspect for damage. Remove and
recycle packing materials. Do not discard the kickplate, anti-
tip bracket, hardware and the leveling legs which hold the
wood base to the bottom of the unit.

MODEL 424G / 424FSG SITE PREPARATION