Anti-tip bracket – Sub-Zero 427G User Manual
Page 13

subzero.com
|
13
MODEL 427G / 427RG SITE PREPARATION
Anti-Tip Bracket
WARNING
To prevent the unit from tipping forward, the anti-tip
bracket must be installed.
The back of the anti-tip bracket must be installed 24"
(610)
from the front of the unit (without panels).
Use all anti-tip bracket hardware as instructed for wood or
concrete floors.
IMPORTANT NOTE:
For wood or concrete floor applications,
if the #12 screws do not hit a wall stud or wall plate, use the
#8 screws and #12 washers with the wall anchors.
IMPORTANT NOTE:
In some installations the subflooring or
finished floor may necessitate angling the screws used to
fasten the anti-tip bracket to the back wall.
ANTI-TIP HARDWARE
1
Anti-tip bracket
12
#12 x 2
1
/
2
" pan head screws
4
3
/
8
"–16 x 3
3
/
4
" wedge anchors
12
#12 flat washers
4
#8–18 x 1
1
/
4
" truss head screws
4
Nylon Zip-it
®
wall anchors
WOOD FLOOR
After properly locating the anti-tip bracket in the opening,
drill pilot holes
3
/
16
"
(5)
diameter maximum in the wall studs
or wall plate. Use the #12 screws and washers to secure the
brackets. Verify the screws penetrate through the flooring
material and into wall studs or wall plate a minimum of
3
/
4
"
(19)
. Refer to the illustration and chart below.
CONCRETE FLOOR
After properly locating the anti-tip bracket in the opening,
drill pilot holes
3
/
16
"
(5)
diameter maximum in the wall studs
or wall plate. Drill
3
/
8
"
(10)
diameter holes into the concrete
a minimum of 1
1
/
2
"
(38)
deep. Use the #12 screws and
washers to secure the brackets to the wall, and use the
3
/
8
"
wedge anchors to secure the brackets to the floor. Verify
the screws penetrate wall studs or wall plate a minimum of
3
/
4
"
(19)
. Refer to the illustration and chart below.
ANTI-TIP BRACKET
MODEL
A
427G and 427RG
13
1
/
2
"
(343)
A
A
SUBFLOORING
WOOD FLOOR
WALL PLATE
FINISHED
FLOORING
A
A
SUBFLOORING
CONCRETE
FLOOR
WALL PLATE
FINISHED
FLOORING
1
1
/
2
"
(38)
min
Wood floor.
Concrete floor.