Sub-Zero Customer Care 800.222.7820

MODEL WS-30 INSTALLATION

ANCHORING

After the unit has been leveled and door adjustment com-
pleted, anchor the unit to the opening to ensure a proper fit
and secure installation.

To anchor the top of the unit, open the grille and install the
screws provided, through the grille frame into cabinetry.
There are several hole locations. Refer to the illustration
below. Check for proper door clearance by opening the
door.

To anchor the bottom of the unit, drive a screw through the
side hole inside each roller base assembly. The screw will
need to go in at an angle to attach properly. Refer to the
illustration below. Additional material may be needed behind
the cleat to ensure sufficient anchoring.

CAUTION

If the screws provided are not suitable for the installa-
tion, use adequate screws.

ANCHORING

SCREWS

ANCHORING

SCREW


Top anchoring.


Bottom anchoring.

Completion

HOME SECURITY CONNECTION

If the unit will be connected to a home security system,
make connections to the leads

shown in the illustration

below. Refer to the following color codes:

t

Normally open contacts—white with red stripe wire.

t

Normally closed contacts—white with blue stripe wire.

t

Common—gray with white stripe wire.

Use the spade terminals or wire nuts provided to make
proper wiring connections.

CAUTION

The alarm circuit in the unit is intended as a low-
voltage, low-current device only. It should not be used
to switch line power. Any unused terminals should be
completely insulated and all wires should be secured
away from conductive or moving components.