Instructions for the user – Smeg SCA130P User Manual
Page 21

Instructions for the User
23
ON
-
ON
300 °C
OFF
500 °C
OFF
300 °C
12.6.3 Setting the cleaning cycle with electronic programmer
FUNCTION SELECTOR KNOB
CLEANING CYCLE MINIMUM DURATION: 1 h and 30’
Turn the function selector knob to the
symbol: the thermostat light will come on and the programmer
will automatically set on a minimum Pyrolysis duration of
. To display or adjust this duration,
press the
key and the increase/decrease keys
or
. The duration of the pyrolysis cycle can be
set up to a maximum of 3 hours.
The cleaning cycle can be programmed to start at a preset time. Press the
key and adjust the values
using the value variation keys
or
.
12.6.4 How the automatic cleaning cycle works (for models with electronic analogue clock)
The table below shows an example of operation of the automatic cleaning cycle.
One minute after the start of the pyrolysis cycle, an interlock device which prevents opening of the door
is tripped and number 12 on the timer starts to flash.
The door interlock is only released later, when the temperature inside the oven drops back below 300°C,
and number 12 on the timer stops flashing.