Error messages – Sony SRX- R110 User Manual
Page 33
33
GB
Error Messages
Chap
ter
5
Ot
he
rs
Error Messages
The error messages are displayed in the STATUS MESSAGE window on the projector and the Error display window of
the SRX Controller. If there are two or more messages, a displayed message changes each 5 seconds. Use the list below
to check the meaning of the error, and consult with qualified Sony personnel. Be sure to inform them of the displayed
messages and their numbers.
No.
Error messages
Meaning
1
INPUT-A POWER ALERT
Trouble with power of INPUT A board
2
INPUT-B POWER ALERT
Trouble with power of INPUT B board
3
INPUT-C POWER ALERT
Trouble with power of INPUT C board
4
INPUT-D POWER ALERT
Trouble with power of INPUT D board
5
PR-284_1 POWER ALERT
Trouble with power of PR-284 board at the top
6
PR-284_2 POWER ALERT
Trouble with power of PR-284 board on the second row
7
PR-284_3 POWER ALERT
Trouble with power of PR-284 board on the third row
8
PR-284_4 POWER ALERT
Trouble with power of PR-284 board on the fourth row
9
24V POWER SUPPLY ALERT
The projector has failed to supply 24V power.
10
16V POWER SUPPLY ALERT
The projector has failed to supply 16V power.
11
PR-284_1 DETACHED
The PR-284 board is not attached correctly on the top row.
12
SXRD PANEL TEMPERATURE
ALERT
The temperature of the panels is too high.
13
LAMP_A FAN ALERT
Trouble with the for Lamp A, or the harness is disconnected or down.
14
LAMP_B FAN ALERT
Trouble with the for Lamp B, or the harness is disconnected or down.
15
LAMP_A POWER SUPPLY UNIT
FAN ALERT
Trouble with the ballast fan for Lamp A power, or the harness is disconnected or down.
16
LAMP_B POWER SUPPLY UNIT
FAN ALERT
Trouble with the ballast fan for Lamp B power, or the harness is disconnected or down.
17
PR-284 FAN ALERT
Trouble with the fan for PR-284 board, or the harness is disconnected or down.
18
OPTICAL UNIT TEMPERATURE
ALERT
The temperature of the optical unit is too high, or the harness is disconnected or down.
19
LAMP_A TEMPTEMPERATURE
ALERT
The temperature of Lamp A is too high, or the harness is disconnected or down.
20
LAMP_B TEMPTEMPERATURE
ALERT
The temperature of Lamp B is too high, or the harness is disconnected or down.
21
LAMP_A HOUSE DETACHED
The projection lamp house of Lamp A is not installed correctly, or the harness is
disconnected or down.
22
LAMP_B HOUSE DETACHED
The projection lamp house of Lamp B is not installed correctly, or the harness is
disconnected or down.
23
REAR COVER DETACHED
The rear cover is open, or the harness is disconnected or down.
24
LAMP_A POWER SUPPLYUNIT
ALERT
Trouble with the power (ballast) of Lamp A
25
LAMP_B POWER SUPPLY UNIT
ALERT
Trouble with the power (ballast) of Lamp B
26
LAMP_A IGNITION FAILURE
Lamp A does not turn on.
27
LAMP_B IGNITION FAILURE
Lamp B does not turn on.
28
CPU ALERT
Trouble with the main CPU (IC301) on the SY-321. Serious trouble
29
MUTING OFF FAILURE
DOUSER OPEN FAILURE
Trouble with opening/shutting of the shutter, or the harness is disconnected or down.
30
INPUT BOARD FAN ALERT
Trouble with the HIF fan next to the INPUT A/B/C/D boards, or the harness is
disconnected or down.