beautypg.com

Error messages – Sony SRX- R110 User Manual

Page 33

background image

33

GB

Error Messages

Chap

ter
5

Ot
he
rs

Error Messages

The error messages are displayed in the STATUS MESSAGE window on the projector and the Error display window of
the SRX Controller. If there are two or more messages, a displayed message changes each 5 seconds. Use the list below
to check the meaning of the error, and consult with qualified Sony personnel. Be sure to inform them of the displayed
messages and their numbers.

No.

Error messages

Meaning

1

INPUT-A POWER ALERT

Trouble with power of INPUT A board

2

INPUT-B POWER ALERT

Trouble with power of INPUT B board

3

INPUT-C POWER ALERT

Trouble with power of INPUT C board

4

INPUT-D POWER ALERT

Trouble with power of INPUT D board

5

PR-284_1 POWER ALERT

Trouble with power of PR-284 board at the top

6

PR-284_2 POWER ALERT

Trouble with power of PR-284 board on the second row

7

PR-284_3 POWER ALERT

Trouble with power of PR-284 board on the third row

8

PR-284_4 POWER ALERT

Trouble with power of PR-284 board on the fourth row

9

24V POWER SUPPLY ALERT

The projector has failed to supply 24V power.

10

16V POWER SUPPLY ALERT

The projector has failed to supply 16V power.

11

PR-284_1 DETACHED

The PR-284 board is not attached correctly on the top row.

12

SXRD PANEL TEMPERATURE
ALERT

The temperature of the panels is too high.

13

LAMP_A FAN ALERT

Trouble with the for Lamp A, or the harness is disconnected or down.

14

LAMP_B FAN ALERT

Trouble with the for Lamp B, or the harness is disconnected or down.

15

LAMP_A POWER SUPPLY UNIT
FAN ALERT

Trouble with the ballast fan for Lamp A power, or the harness is disconnected or down.

16

LAMP_B POWER SUPPLY UNIT
FAN ALERT

Trouble with the ballast fan for Lamp B power, or the harness is disconnected or down.

17

PR-284 FAN ALERT

Trouble with the fan for PR-284 board, or the harness is disconnected or down.

18

OPTICAL UNIT TEMPERATURE
ALERT

The temperature of the optical unit is too high, or the harness is disconnected or down.

19

LAMP_A TEMPTEMPERATURE
ALERT

The temperature of Lamp A is too high, or the harness is disconnected or down.

20

LAMP_B TEMPTEMPERATURE
ALERT

The temperature of Lamp B is too high, or the harness is disconnected or down.

21

LAMP_A HOUSE DETACHED

The projection lamp house of Lamp A is not installed correctly, or the harness is
disconnected or down.

22

LAMP_B HOUSE DETACHED

The projection lamp house of Lamp B is not installed correctly, or the harness is
disconnected or down.

23

REAR COVER DETACHED

The rear cover is open, or the harness is disconnected or down.

24

LAMP_A POWER SUPPLYUNIT
ALERT

Trouble with the power (ballast) of Lamp A

25

LAMP_B POWER SUPPLY UNIT
ALERT

Trouble with the power (ballast) of Lamp B

26

LAMP_A IGNITION FAILURE

Lamp A does not turn on.

27

LAMP_B IGNITION FAILURE

Lamp B does not turn on.

28

CPU ALERT

Trouble with the main CPU (IC301) on the SY-321. Serious trouble

29

MUTING OFF FAILURE
DOUSER OPEN FAILURE

Trouble with opening/shutting of the shutter, or the harness is disconnected or down.

30

INPUT BOARD FAN ALERT

Trouble with the HIF fan next to the INPUT A/B/C/D boards, or the harness is
disconnected or down.