Parameter setting commands – Sony SRP-X700P User Manual
Page 18

– 18 –
Parameter Setting Commands
The following commands are the group of commands used to enable you the detailed setting of internal functions of the SRP-X700P.
AUTO MIX : 43[H] 41[H] 4D[H] 58[H] (‘CAMX’)
This command is used to set ON/OFF of the automatic mixer.
•
Packet format
43[H] 41[H] 4D[H] 58[H] “parameter” 0D[H]
The parameter consists of the 5 bytes all the time in the order as shown in the table below.
Example: When turning OFF the automatic mixer
43[H] 41[H] 4D[H] 58[H] 3B[H] 33[H] 40[H] 40[H] 0D[H] ( ‘C A M X ; 3 1 @ @ CR’ )
AUTO MIX PARAMETER REQUEST : 52[H] 41[H] 4D[H] 58[H] (‘RAMX’)
This command is used to read the ON/OFF setup of automatic mixer from the SRP-X700P.
•
Packet format
52[H] 41[H] 4D[H] 58[H] 0D[H]
•
Return packet format
When communication with the SRP-X700P is established with success, the parameter is returned together with ACK (41[H] (‘A’)) in the
order shown below.
41[H] “parameter” 0D[H]
Parameters are the same as those of the AUTO MIX command in the case of ON/OFF.
Example: When the automatic mixer is set to OFF
41[H] 3B[H] 33[H] 40[H] 40[H] 0D[H] ( ‘A ; 3 1 @ @ CR’ )
FACTORY PRESET : 43[H] 52[H] 53[H] 54[H] ( ‘CRST’ )
This command is used to return the parameters of the SRP-X700P to the default values when shipped from the factory.
•
Packet format
43[H] 52[H] 53[H] 54[H] 0D[H]
When communication with the SRP-X700P is established with success, all parameters including scene memories return to the default
state when shipped from the factory.
Caution
When the parameters are returned to the default state when shipped from the factory, all parameters that have been set by users will be
overwritten.
Before starting to execute this command, create backup of the parameter values using the supplied software SRP-X700P Manager.
byte
ON
OFF
1st
3B[H] (‘;’)
3B[H] (‘;’)
2nd
33[H] (‘3’)
33[H] (‘3’)
3rd
31[H] (‘1’)
31[H] (‘1’)
4th
43[H] (‘C’)
40[H] (‘@’)
5th
7F[H] (‘DELETE’)
40[H] (‘@’)