Si4421, Control commands – Silicon Laboratories SI4421 User Manual
Page 14
Si4421
Control Commands
Control Command
Related Parameters/Functions
Related control bits
1
Configuration Setting Command
Frequency band, crystal oscillator load capacitance,
RX FIFO and TX register enable
el
, ef, b1 to b0, x3 to x0
2
Power Management Command
Receiver/Transmitter mode change, synthesizer,
crystal oscillator, PA, wake-up timer, clock output
enable
er
, ebb, et, es, ex, eb, ew, dc
3
Frequency Setting Command
Frequency of the local oscillator/carrier signal
f11
to f0
4
Data Rate Command
Bit rate
cs
, r6 to r0
5
Receiver Control Command
Function of pin 16, Valid Data Indicator, baseband
bandwidth, LNA gain, digital RSSI threshold
p16
, d1 to d0, i2 to i0, g1 to g0, r2
to r0
6
Data Filter Command
Data filter type, clock recovery parameters
al
, ml, s, f2 to f0
7
FIFO and Reset Mode Command
Data FIFO IT level, FIFO start control, FIFO enable
and FIFO fill enable, POR sensitivity
f3
to f0, sp, ff, al, dr
8
Synchron Pattern Command
Synchron pattern
b7
to b0
9
Receiver FIFO Read Command
RX FIFO read
10
AFC Command
AFC parameters
a1
to a0, rl1 to rl0, st, fi, oe, en
11
TX Configuration Control Command
Modulation parameters, output power
mp
, m3 to m0, p2 to p0
12
PLL Setting Command
CLK out buffer speed, dithering, PLL bandwidth
ob1
to ob0, ddit, dly, bw0
13
Transmitter Register Write Command
TX data register write
t7
to t0
14
Wake-Up Timer Command
Wake-up time period
r4
to r0, m7 to m0
15
Low Duty-Cycle Command
Enable and set low duty-cycle mode
d6
to d0, en
16
Low Battery Detector and
Microcontroller Clock Divider
Command
LBD voltage and microcontroller clock division ratio
d2
to d0, v3 to v0
17
Status Read Command
Status bit readout
In general, setting the given bit to one will activate the related function. In the following tables, the POR column shows the default
values of the command registers after power-on.
Control Register Default Values
Control Register
Power-On Reset Value
1
Configuration Setting Command
2
Power Management Command
3
Frequency Setting Command
4 Data
Rate
Command
5
Receiver Control Command
6
Data Filter Command
7
FIFO and Reset Mode Command
8
Synchron Pattern Command
9
Receiver FIFO Read Command
10 AFC
Command
11
TX Configuration Control Command
12
PLL Setting Command
13
Transmitter Register Write Command
14 Wake-Up
Timer
Command
15
Low Duty-Cycle Command
16
Low Battery Detector and Microcontroller Clock Divider Command
17
Status Read Command
14