Hsfs: hsnode table full (bugids4082275, 4475306), Hsfs: hsnode, Intermittent – Sun Microsystems Sun Fire 880 User Manual

Page 29

background image

Sun Fire 880 Server Product Notes

23

receiving power. To determine if a fan is faulty, check its fan speed displayed in the

prtdiag

output. A fan speed of zero should be interpreted as a fan failure. Also,

any fan failure will light the fan tray’s Fault LED and the System Fault and Thermal
Fault LEDs on the server’s front panel.

Note –

Patch 110849-08 or later fixes this issue. See “Required And Recommended

Software Patches” on page 3.

hsfs: hsnode

table full (BugIDs 4082275,

4475306)

For a Sun Fire 880 system running the Solaris 8 7/01 operating environment, if you
attempt to set up the system as a Solaris install server, the following error message
may appear during installation of the install server packages or patches:

NOTICE: hsfs: hsnode table full

If this message appears, the software installation will terminate prior to completion,
and the install server software will be only partially installed.

Workaround – To recover from this situation, add the following line to the

/etc/system

file and reboot the system:

set hsfs:nhsnode=1000

Once the system has booted, repeat the procedure for setting up the install server.

Intermittent

picld

errors during power supply

hot-plug (BugID 4431165)

On Sun Fire 880 systems running the Solaris 8 7/01 or 8 10/01 operating
environment, the following

picld

error messages may be temporarily generated

after hot-swapping a redundant power supply:

ERROR running psvc_ps_device_fail_notifier_policy_0

No such device or address

ERROR running psvc_ps_overcurrent_check_policy_0

No such device or address

These warnings do not indicate a problem with the server or power supply. For a
brief time during the hot-swap operation, the environmental monitoring software is
unable to monitor the environmental conditions of the power supply, which results
in the error messages. This state is temporary, however, as full monitoring
capabilities are restored within 30 seconds.

Note –

Patch 110849-08 or later fixes this issue. See “Required And Recommended

Software Patches” on page 3.