beautypg.com

Correction to fru part numbers, Ordering dimms, Part number corrections – Sun Microsystems Sun Fire 880 User Manual

Page 21

background image

Sun Fire 880 Server Product Notes

15

Correction to FC-AL Disk Cage Installation
Procedure

The procedure “How to Install the FC-AL Disk Cage” as documented in the
Sun Fire 880 Server Service Manual is incomplete. The following task should be
included as Step 9c:

9c. If a Sun StorEdge PCI Dual Fibre Channel Host Adapter card is installed to

control Loop B of the FC-AL disk backplane, connect the card’s FC-AL data cable
to the base backplane at connectors C(J01100) and D(J01101).

Correction to FRU Part Numbers

Ordering DIMMs

DIMMs for the Sun Fire 880 are no longer available in kits of four DIMMs. The
following table lists the single DIMMs and their part numbers for the Sun Fire 880.

Part Number Corrections

Appendix A of the Sun Fire 880 Server Service Manual lists incorrect part numbers for
the following field-replaceable units (FRUs):

18 GB 10K FC-AL Disk Drive - this drive is not supported in the system

72 GB 10K FC-AL Disk Drive

The correct FRU part numbers are as follows.

Note –

Disk drive capacities lower than 36 Gbytes are not supported on the

Sun Fire 880 server.

DIMM Description

Part Number

128 MB DIMM

501-4489

256 MB DIMM

501-5401

512 MB DIMM

501-5030

Part Description

Incorrect Part Number

Correct Part Number

18 GB 10K FC-AL Disk Drive

540-4191

Not supported in the Sun
Fire 880 server

72 GB 10K FC-AL Disk Drive

540-4519

540-4905