Correction to fru part numbers, Ordering dimms, Part number corrections – Sun Microsystems Sun Fire 880 User Manual
Page 21
Sun Fire 880 Server Product Notes
15
Correction to FC-AL Disk Cage Installation
Procedure
The procedure “How to Install the FC-AL Disk Cage” as documented in the
Sun Fire 880 Server Service Manual is incomplete. The following task should be
included as Step 9c:
9c. If a Sun StorEdge PCI Dual Fibre Channel Host Adapter card is installed to
control Loop B of the FC-AL disk backplane, connect the card’s FC-AL data cable
to the base backplane at connectors C(J01100) and D(J01101).
Correction to FRU Part Numbers
Ordering DIMMs
DIMMs for the Sun Fire 880 are no longer available in kits of four DIMMs. The
following table lists the single DIMMs and their part numbers for the Sun Fire 880.
Part Number Corrections
Appendix A of the Sun Fire 880 Server Service Manual lists incorrect part numbers for
the following field-replaceable units (FRUs):
■
18 GB 10K FC-AL Disk Drive - this drive is not supported in the system
■
72 GB 10K FC-AL Disk Drive
The correct FRU part numbers are as follows.
Note –
Disk drive capacities lower than 36 Gbytes are not supported on the
Sun Fire 880 server.
DIMM Description
Part Number
128 MB DIMM
501-4489
256 MB DIMM
501-5401
512 MB DIMM
501-5030
Part Description
Incorrect Part Number
Correct Part Number
18 GB 10K FC-AL Disk Drive
540-4191
Not supported in the Sun
Fire 880 server
72 GB 10K FC-AL Disk Drive
540-4519
540-4905