SRP-X500P RS-232C Interface Manual

FR (50th-53rd byte)

The FR parameter consists of the 4 bytes of data in the order shown in the following table.

Byte Parameter

1st

MIC 1/WL 1 FR

2nd

MIC 2/WL 2 FR

3rd

MIC 3 FR

4th

MIC 4 FR

FR

Shows the status of the FEED BACK REDUCER. The correspondence of the parameter with
the FEED BACK REDUCER setting is shown in the following table.

FR

Turned off

0x30 (‘0’)

Turned on

0x31 (‘1’)

Setting up in progress

0x32 (‘2’)

Cancellation in progress

0x33 (‘3’)

FR SETUP STATUS (54th and 55th byte)

The FEED BACK REDUCER setup status parameter consists of the 2 bytes of data in the order shown
in the following table.

Byte Parameter

1st SETUP

CHANNEL

2nd SETUP

STATUS

SETUP CHANNEL

Shows the channel for which the FEED BACK REDUCER setting is in progress.
The parameter and the channel are shown in the following table.

Channel

Normal operation

0x30 (‘0’)

MIC 1/WL 1

0x31 (‘1’)

MIC 2/WL 2

0x32 (‘2’)

MIC 3

0x33 (‘3’)

MIC 4

0x34 (‘4’)

CANCEL 0x35

(‘5’)