Connection, Operating your camera – Samsung SVD-4600 User Manual
Page 7

COLOR CCD CAMERA
User Guide
12
COLOR CCD CAMERA
User Guide
13
Using a RS-485 communication, it will be able to control the OSD menu at the
SAMSUNG TECHWIN System Controller or DVR.
(1) The case which it controls from the PC
Using a RS-485 converter, It connects to RS-485 control cable outside camera
and serial cable
EX) SERIAL PORT OF THE PC(COM1) → SERIAL CABLE → RS-485 CONVERTER → RS-485
CONTROL CABLE
(2)The case which it controls from the DVR or System Controller
It connects the RS-485 control cable in the connection terminal of 485 control
boards which are connected with the DVR or System Controller.
Connecting to RS-485 Control Cable
• When you construct external control systems for a camera control, please use to the SAMSUNG
TECHWIN PROTOCOL or PELCO-D PROTOCOL.
• When you connecting to RS-485 control cable, please peel off the outer skin inside the RS-485
control cable.
• In case of SCC-101 connection, change communication mode to 『8-E-1』 at 『Communication
configuration』menu. (For more information, refer to SCC-101 manual.)
Notes
* RS-485 Communication establishment initial value
Connection
485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL
RED (TRX+)
(-) CONNECTION TERMINAL
WHITE (TRX-)
CONTROL CABLE
SPEC
RED (TRX+)
RS-485+
WHITE(TRX-)
RS-485-
Item
Camera ID
BAUD RATE
UART MODE
RET PKT
Initial value
1
9600
8-NONE-1
ENABLE
Setup Menu
LENS
●DC
EXPOSURE
●SHUTTER…
●AGC…………………
● SENS-UP………
● RETURN…
WHITE BALANCE
● ATW…
●MANUAL…
●AWC→SET…
●OUTDOOR…
● INDOOR
BACKLIGHT
●
OFF
…
●
WDR
●
BLC
●
HLC
SSNR
●
ON
…
●
OFF
DAY/NIGHT
●
COLOR
…
●
B/W
…
●
AUTO
IMAGE ADJUSTMENT
(IMAGE ADJ.)
●
FREEZE
…
●
V-REV
………
●
H-REV
…
●
D-ZOOM
…
●
SHARPNESS
………… ●
RETURN
SPECIAL
●
CAMTITLE
…
●
SYNC
………
●
MOTION DET
●
PRIVACY
…
●
DIS
……
●
COMM ADJ
…
●
LANGUAGE
…
●
RESET
…
●
RETURN
EXIT
Operating Your Camera
Use the Function Setup switch on back of the camera.
Function Setup switch
RS-485 communication control
Menu Setup
Menu Configuration