Site Preparation

6

FRONT VIEW

15

1

/

2

"

(394)

3"

(76)

2"

(51)

LEFT SIDE

OF OPENING

Location of electrical supply.

Plumbing Requirements

MODEL UC-24CI

For model UC-24CI, the water supply line for the ice

maker should be located within the shaded area shown in

the illustration below. Connect the water line from the ice

maker water valve to the house water supply line. Use an

easily accessible shut-off valve between the water supply

and the unit. Do not use self-piercing valves. A saddle

valve kit is available from your authorized Sub-Zero

dealer.

A line filter is required when water conditions have a high

sediment content. The ice maker operates on water

pressure of 20 psi

(1.4 bar)

to 100 psi

(6.9 bar)

.

A reverse osmosis system can be used, provided there is

a consistent water pressure of 20 psi

(1.4 bar)

to 100 psi

(6.9 bar)

supplied to the water valve at all times. A copper

line is not recommended for this application.

IMPORTANT NOTE:

In some cases a reverse osmosis

water filter system may not be able to maintain the

minimum water pressure consistently.

FRONT VIEW

SHADED AREA

EXTENDS 1

/

2

"

(13)

FROM BACK WALL

15

1

/

2

"

(394)

3"

(76)

2"

(51)

Location of water supply.

Electrical Requirements

The electrical supply should be located within the shaded

area shown in the illustration below. Follow the National

Electrical Code and local codes and ordinances when

installing the receptacle. A separate circuit, servicing only

this appliance is required.

IMPORTANT NOTE:

The electrical outlet must be placed

so the grounding prong is to the right of the thinner

blades. The outlet must be flush with the back wall.

Model UC-24RO is designed and safe for use in outdoor

applications. When installed outdoors, a ground fault

circuit interrupter (GFCI) is required to reduce the risk of

electrical shock. A GFCI is not recommended for use with

other undercounter models and may cause interruption of

operation.

Electrical Requirements

Power Supply

115 V AC, 60 Hz

Circuit Breaker

15 amp

Receptacle

3-prong grounding-type

Do not use an extension cord or two-prong adapter.

Electrical ground is required on this appliance.

Plumbing Requirements

Water Supply Line

1

/

4

" OD copper, braided stainless steel

or PEX tubing

Water Pressure

20–100 psi

(1.4–6.9 bar)

Excess Water Line for Connection

26"

(660)

min