2 verifying the installation – Sun Microsystems SunSwift SPARCcenter 2000 User Manual
Page 18
2-2
SunSwift SBus Adapter Installation and User’s Guide—December 1995
2
2.2 Verifying the Installation
Refer to the Solaris 2.5 Handbook for SMCC Peripherals manual or your Solaris
documentation for detailed instructions for the following tasks.
1. Power on the system, and when the banner appears, press the Stop-A keys
to interrupt the boot process and get to the
ok
prompt.
2. Use the
show-devs
command to list the devices in the system.
You should see two lines (similar to the example below) in the display,
specific to the SunSwift SBus Adapter:
•
fas@0
identifies the adapter’s SCSI-2 device.
•
hme@0
identifies the adapter’s Ethernet device.
Note – In the above example, the number
0
following
fas@
and
hme@
corresponds to the instance number of the SunSwift SBus Adapter installation.
The numbers you see when listing the system devices may be different.
If you do not see these devices listed, check that the adapter is properly seated
and reinstall the adapter, if necessary.
ok show-devs
...
/iommu@f,e0000000/sbus@f,e0001000/SUNW,fas@0,8800000
/iommu@f,e0000000/sbus@f,e0001000/SUNW,hme@0,8c00000
...