• This unit operates under SELV (Safety Extra Low Voltage) conditions according to

IEC 60950. The conditions are only maintained if the equipment to which it is connected
also operates under SELV conditions.

France and Peru only
This unit cannot be powered from IT

supplies. If your supplies are of IT type, this unit must

be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary
connection point labelled Neutral, connected directly to earth (ground).

Impédance à la terre

Important! Before making connections, make sure you have the correct cord set. Check it
(read the label on the cable) against the following:

Power Cord Set

U.S.A. and Canada

The cord set must be UL-approved and CSA certified.

The minimum specifications for the flexible cord are:

- No. 18 AWG - not longer than 2 meters, or 16 AWG.

- Type SV or SJ

- 3-conductor

The cord set must have a rated current capacity of at least 10 A

The attachment plug must be an earth-grounding type with NEMA

5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.

Denmark

The supply plug must comply with Section 107-2-D1, Standard

DK2-1a or DK2-5a.

Switzerland

The supply plug must comply with SEV/ASE 1011.

U.K.

The supply plug must comply with BS1363 (3-pin 13 A) and be

fitted with a 5 A fuse which complies with BS1362.

The mains cord must be or marked and be of

type HO3VVF3GO.75 (minimum).

Europe

The supply plug must comply with CEE7/7 (“SCHUKO”).

The mains cord must be or marked and be of

type HO3VVF3GO.75 (minimum).

IEC-320 receptacle.