beautypg.com

Slant/Fin VHS-180 User Manual

Page 2

background image

V

ICTORY

II

VHS Models

NOTE: Height dimensions increase by 1

3

4

" and depth increases to 22

1

4

" when combustible floor kit is used.

Natural

#49

50

50

50

51

51

51

52 52 52

Propane

#57

58

59

59

60

60

61

62

63

63

VHS-30

30,000

2

8

1

8

"

14

5

8

"

190

VHS-60

60,000

3

11

1

8

"

17

5

8

"

250

VHS-90

90,000

4

14

1

8

"

20

5

8

"

310

VHS-120

120,000

5

17

1

8

"

23

5

8

"

365

VHS-150

150,000

6

20

1

8

"

26

5

8

"

425

VHS-180

180,000

7

23

1

8

"

29

5

8

"

485

Boiler
Model

No. of

Sections

Input

Btuh

A

B

Approx.

Total Wt.

Full of

Water (lb.)

Gas

Type

2000

3000 4000 5000 6000

7000 8000 9000 10000

Orifice

Size for

Sea Level

Orifice Sizes for High Altitudes

Includes 4% Reduction for Each 1000 Feet

Elevation — Feet

Orifice sizes indicated for sea level above are factory installed in boiler unless otherwise specified
by the local authority. Orifice table is based on a higher heating value between 1000 Btuh and
1010 Btuh for Natural Gas (See page 19, if local higher heating value exceeds these numbers).
See page 19, for burner input adjustment.

LEFT END VIEW

FRONT VIEW

RIGHT END VIEW

Figure 1. Views - Dimensions - Data

Figure 2. Base Assembly Victory II - VHS Boiler

2

Gas manifold

Burners

Pilot

Burner
access door

Gas valve

This manual is related to the following products: