Slant/Fin GXHA Series User Manual
Ratings chart – gas boilers, Galaxy gx (h), gxha series
®
RATINGS CHART – GAS BOILERS
GALAXY GX (H), GXHA SERIES
©Slant/Fin Corp. 2007
GXHA-100
100,000
—
81,000
—
—
61,000
254
2
1/
2
GXH-105
105,000
86,000
—
495
75,000
—
—
2
1/
2
GXHA-120
120,000
—
97,000
—
—
73,000
304
3
GXH-125
126,000
104,000
—
600
90,000
—
—
3
GXH-150
147,000
120,000
—
695
104,000
—
—
3
1/
4
GXHA-160
160,000
—
130,000
—
—
98,000
408
3
1/
2
GXH-170
168,000
137,000
—
795
119,000
—
—
3
1/
2
GXH-190
189,000
155,000
—
895
135,000
—
—
3
3/
4
GXHA-200
200,000
—
163,000
—
—
122,000
508
4
GXH-210
210,000
172,000
—
995
150,000
—
—
4
GX-225
225,000
184,000
—
1065
160,000
—
—
4
GXH-230
231,000
189,000
189,000
1095
164,000
142,000
591
4
1/
4
GX-250
250,000
204,000
—
1180
177,400
—
—
4
1/
2
GXH-250
252,000
206,000
206,000
1195
179,000
155,000
646
4
1/
2
GXH-275
273,000
223,000
223,000
1290
194,000
167,000
696
5
GXH-300
300,000
240,000**
240,000 **
1395
209,000
180,000
750
5
1/
2
GXH-300H§
300,000
243,000**
243,000 **
1405
211,000
182,000
758
5
1/
2
MODEL
NUMBER †
CSA
INPUT
(Btuh)
D.O.E.
CAPACITY
WATER
(Btuh)
D.O.E.
CAPACITY
STEAM
(Btuh)
WATER
(Sq.Ft.)
WATER
(Btuh)
STEAM
(Btuh)
STEAM
(Sq.Ft.)
TANKLESS
HEATER
CAPACITY
(G.P.M.)‡
RATINGS STEAM OR WATER
NET I=B=R*
EFFICIENCY
GALAXY DOE SEASONAL
EFFICIENCY (AFUE)*
GXH-105 ED
81.00
GXH-125 ED
81.00
GXH-150 ED
81.14
GXH-170 ED
81.14
GXH-190 ED
81.14
GXH-210 ED
81.17
GX-225 ED
81.30
GXH-230 ED
81.21
GX-250 ED
80.70
GXH-250 ED
81.24
GXH-275 ED
81.28
GXHA-100 ED
81.00
GXHA-120 ED
81.20
GXHA-160 ED
81.20
GXHA-200 ED
81.30
MODEL
Natural and L.P. Propane Gas
± GG models: Add suffix “S” for standard water boiler, “P” for
packaged water boiler. Add suffix “E” for intermittent pilot igni-
tion system (available only with 24 volt gas valve). Type of
gas: After model number, specify gas by name “Natural” or
“Propane”
*
Net ratings are based on a piping and pick-up allowance of
1.33 (steam) and 1.15 (hot water). Slant/Fin should be con-
sulted before selecting a boiler for installation having
unusual piping and pick-up requirements. Ratings must
be reduced by 4% at 2,000 feet elevation and an addition
al 4% for every additional 1,000 feet elevation over 2,000
feet.
† GXH and GX models: Add suffix “PT” for standard water
boiler with tankless heater, “PZ” for steam boiler, “PZT” for
packaged steam boiler with tankless heater. Add suffix “E”
for intermittent pilot ignition system (available only with 24
volt gas valve). Type of gas: After model number, specify
gas by name “Natural” or “Propane”.
** CSA output rating (Btuh).
§ Ratings for GXH-300H are for natural gas only.
‡ Tankless heater ratings based on intermittent draw.
NOTE: All boilers under 300,000 Btu input are tested and
rated for capacity under the U.S. Dept. of Energy (D.O.E.)
Test Procedure for boilers.
* Includes intermittent pilot and
vent damper. Annual Fuel
Utilization Efficiency based on
constant circulation for hot
water models.
SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600
FAX: (516) 484-5921 • In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario
www.slantfin.com
DISCONTINUED MODEL
NOTE: GXH-230 (WATER MODEL DISCONTINUED ONLY)
STEAM MODELS ARE AVAILABLE