beautypg.com

8 technical information, 9 the rating plate, 10 electrical connection – Smeg SE2642ID3 User Manual

Page 25: Instructions for the installer

background image

Instructions for the installer

53

11.8 Technical information

• Hob model See rating plate
• Electrical connections 220-240V~ 50/60Hz / 380-415V 2N~ 50/60Hz
HOB RATING I
• Maximum power See rating plate

11.9 The rating plate

Make sure that the voltage and capacity of the power line conform to the data shown on the plate
located under the casing. Do not remove this plate for any reason.

11.10 Electrical connection

• The electrical connection of the hob must be installed by an authorised technician.
• The applicable legislation and rules for connection to the local electricity supplier must be followed.
• Disconnect the appliance from the power supply, using one of these devices, when you want to

connect it to the supply or carry out repairs.

• The earthing wire must be longer than the current conduction wires so that, if the plug is torn off the

power cable, it is the last to be detached.

• Surplus parts of the cable must be taken out of the installation area under the appliance.
• To make the connection, the control cover underneath the

device must be loosened so that the terminal board can be
reached. Once the connection has been made, the cover
must be fixed back in place and the cable must be locked
using a traction-resistant clamp.

• The connection cable must correspond to type H05 V2V2-F

as a minimum.

• If the appliance connection cable is damaged, it must be

replaced by the manufacturer, their Technical Support
Service or a qualified technician to avoid any danger.

• When the appliance has been installed, it must be protected

from accidental contact with the electric cables.

• Warning! The electronic controls could be damaged beyond repair if the connection is not

professionally carried out.

IT IS OBLIGATORY FOR ALL ELECTRICAL EQUIPMENT TO BE EARTHED ACCORDING TO THE
METHODS LAID DOWN BY SAFETY REGULATIONS.

WHERE THE APPLIANCE IS CONNECTED TO THE POWER GRID VIA A PLUG AND SOCKET, BOTH
OF THESE MUST BE OF THE SAME TYPE AND CONNECTED TO THE POWER CABLE IN
ACCORDANCE WITH THE APPLICABLE REGULATIONS.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE IS INSTALLED.
NEVER UNPLUG BY PULLING ON THE CABLE.

IMMEDIATELY AFTER INSTALLATION, CARRY OUT A QUICK TEST ON THE APPLIANCE FOLLOWING
THE INSTRUCTIONS PROVIDED EARLIER IN THIS MANUAL. IF IT DOES NOT FUNCTION
CORRECTLY, AFTER HAVING ENSURED THAT THE INSTRUCTIONS HAVE BEEN PROPERLY
FOLLOWED, DISCONNECT THE APPLIANCE FROM THE POWER SUPPLY AND CALL THE NEAREST
TECHNICAL SUPPORT CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.

RUN THE POWER CABLE UNDER THE UNIT, TAKING CARE THAT IT DOES NOT COME INTO
CONTACT WITH THE BOTTOM OF THE CASING OF THE HOB OR THE OVEN BENEATH IT IF THERE
IS ONE.

IF A PLUG AND SOCKET CONNECTION IS USED, CHECK THAT THEY ARE THE SAME TYPE. DO NOT
USE ANY TYPE OF ADAPTOR OR DIVERTER AS THESE MAY CAUSE OVERHEATING OR BURNS.

WHERE A FIXED CONNECTION IS IN USE, A MULTIPOLAR CUT-OUT DEVICE MUST BE
INSTALLED ON THE SUPPLY CABLE WITH A CONTACT OPENING DISTANCE EQUAL OR
GREATER THAN 3 MM, LOCATED IN A READILY REACHABLE POSITION NEAR THE APPLIANCE.