41
The change becomes effective the
next time you turn on the unit by
setting the POWER switch to ON.
4
-b
For the portable diversity
tuner (URX-P1)
Leave the tuner for about 10
seconds until the time indication
stops flashing and the setting is
stored in memory.
Setting the RF output
level
The procedure below is the
same for all UWP series
transmitters (UTX-B1/H1).
You can select an RF output level of
H (30 mW) or L (5 mW) in setting
mode. Set the RF output level to L (5
mW) for simultaneous operation of
multiple channels, and set it to H (30
mW) for long-distance operation.
1
Turn on the transmitter while
pressing down the SET button.
2
Press the SET button repeatedly
until the RF output level
indication appears in the display
section.
3
Press the + button to select H (30
mW), or press the – button to
select L (5 mW).
4
Set the POWER switch to OFF to
complete the setting, or press the
SET button to set other items.
The results are stored in memory.
The change becomes effective the
next time you turn on the
transmitter by setting the POWER
switch to ON.
Setting the monitor
level (portable diversity
tuner (URX-P1) only)
You can set the monitor level for
monitoring the tuner output within the
range of 01 to 24.
1
While the parameters on the
display section are not flashing,
press the + or – button once.
The monitor level indication
appears in the display section.
2
Press the + button to increase the
monitor level, or press the –
button to decrease the level.
When you leave the tuner for
about two seconds or more,
current monitor level setting is
stored in memory and the normal
display resumes. Note that
monitor level setting is effective
after you turn off the tuner, then
turn it on again.