SysKonnect SK-98xx V2.0 User Manual
Page 46
46
6 Testing the Network Adapter
To test the adapter, proceed as follows:
1.
Switch off the computer.
2.
If the computer is still connected to the data network, unplug the data cable from the net-
work adapter’s port.
3.
Connect the network adapter as follows:
•
For the simple test: Insert the protective plugs into the ports.
•
For the loopback test: Insert the loopback connector into the port.
4.
Boot to DOS.
Wait until the operating system is loaded and the DOS prompt is displayed.
5.
Insert the installation CD-ROM into the CD-ROM drive.
6.
Go to the appropriate product directory.
7.
Type
sk98diag
.
8.
Press
9.
From the main menu of the diagnostics program, select one of the following:
•
D
IAGNOSTICS
for the simple test (no loopback)
•
L
OOPB
. W
RAP
P
LUG
for the loopback test or
•
L
OOPB
. P
ORT
TO
P
ORT
for the port-to-port test (only with dual link adapters).
The various components will now be tested; this will take between one and two minutes.
If the test was successful, the following window (or similar) will be displayed:
Figure 6. Typical screen display after a successful test
You can follow the progress of the test in the right-hand window. Each test is displayed as
it is being performed (e.g. B
OARD
REGISTER
CHECK
).
If the test is successful, the word
passed
is issued at the end of the line and the next
test is started. If there is a problem, the word
failed
is issued.
If errors are reported, follow the instructions that are displayed.
10. Check the configuration and, if necessary, repeat the test (see section "Failure of a
Test").
11. To continue testing, press any key.
12. To quit the diagnostics program, select E
XIT
in the main menu.
13. Remove the loopback connector from the port.
14. (Re)connect the ports to the data network