beautypg.com

Step 2: attaching the supplied items (continued) – Sony HVR-Z7E User Manual

Page 12

background image

12

Adjusting the flange focal length
automatically

1

Set the AUTO/MANUAL switch F to
MANUAL.

2

Set the IRIS switch E to MAN.

3

Set the gain to 0dB with the gain switch
H.
If you have not changed the gain switch
setting from the default, set the gain
switch H to L.

Press the GAIN button to enable manual
gain adjustment.

4

Set the shutter speed to automatic
adjustment mode (p. 33).

5

Fully open the aperture with the iris ring
I.

6

Place the flange focal length adjustment
test chart A about 2-3 meters (7-10
feet) away.
Adjust the lighting or the ND filter B
so that a subject is properly lighted.

7

Set the ZOOM switch J to SERVO.

8

Select [AUTO ADJUST] in [FLANGE
BACK] of

(CAMERA SET) menu

(p. 78).

9

Select [YES] with the SEL/PUSH
EXEC dial G.

The flange focal length adjustment starts
and [EXECUTING] appears on the screen.
When the adjustment is completed,
[Completed.] appears on the screen.
If the adjustment fails, [Could not adjust.]
appears on the screen. Try the adjustment
again.

Adjusting the flange focal length
manually

1

Perform steps 1 through 4 of
“Adjusting the flange focal length
automatically.”

2

Set the ZOOM switch J to MANUAL.

3

Select [MANU ADJUST] in [FLANGE
BACK] of

(CAMERA SET)

menu.

4

Select [YES] with the SEL/PUSH
EXEC dial G.

5

Turn the zoom ring D fully to the
telephoto side.

6

Turn the focus ring C until the subject
comes in focus, then press the SEL/
PUSH EXEC dial G.

7

Turn the zoom ring D fully to the wide
angle side.

Step 2: Attaching the supplied items (Continued)