Step 2: attaching the supplied items (continued) – Sony HVR-Z7E User Manual
Page 12
12
Adjusting the flange focal length
automatically
1
Set the AUTO/MANUAL switch F to
MANUAL.
2
Set the IRIS switch E to MAN.
3
Set the gain to 0dB with the gain switch
H.
If you have not changed the gain switch
setting from the default, set the gain
switch H to L.
Press the GAIN button to enable manual
gain adjustment.
4
Set the shutter speed to automatic
adjustment mode (p. 33).
5
Fully open the aperture with the iris ring
I.
6
Place the flange focal length adjustment
test chart A about 2-3 meters (7-10
feet) away.
Adjust the lighting or the ND filter B
so that a subject is properly lighted.
7
Set the ZOOM switch J to SERVO.
8
Select [AUTO ADJUST] in [FLANGE
BACK] of
(CAMERA SET) menu
9
Select [YES] with the SEL/PUSH
EXEC dial G.
The flange focal length adjustment starts
and [EXECUTING] appears on the screen.
When the adjustment is completed,
[Completed.] appears on the screen.
If the adjustment fails, [Could not adjust.]
appears on the screen. Try the adjustment
again.
Adjusting the flange focal length
manually
1
Perform steps 1 through 4 of
“Adjusting the flange focal length
automatically.”
2
Set the ZOOM switch J to MANUAL.
3
Select [MANU ADJUST] in [FLANGE
BACK] of
(CAMERA SET)
menu.
4
Select [YES] with the SEL/PUSH
EXEC dial G.
5
Turn the zoom ring D fully to the
telephoto side.
6
Turn the focus ring C until the subject
comes in focus, then press the SEL/
PUSH EXEC dial G.
7
Turn the zoom ring D fully to the wide
angle side.
Step 2: Attaching the supplied items (Continued)