Pan/Tilt and Telemetry Equipment

Pan/Tilt Telemetry Receivers/Drivers

4-7

© Siemens Building Technologies Group

4

Type

Order No.

CDC0501

Telemetry Receiver for Control Pan-Tilt Heads

Weatherproof telemetry receiver for control pan-tilt units and motor-
driven zoom lenses. 3 auxilliary contacts are available to trigger exter-
nal devices. The drivers can be controlled either via a SIMATRIX SYS‚
Neo‚ 648 or 164 video matrix or from the CKA3210 and CKA4820 con-
trol keyboards directly. The control unit is designed for operating pan-
and-tilt heads with a power supply of 230 V AC‚ 115 V AC or 24 V AC.
Up to 99 addresses can be selected using DIP switches.
6 x M16‚ 2 x M20 and 1 x M26 glands are provided for cabling.

Address codes

99

Power requirements

230 V AC / 115 V AC‚ 50/60 Hz

Dimensions (W x H x D)

280 x 190 x 130 mm

Auxiliary relays

3

Compatible with

CKA3210‚ CKA4820‚ SIMATRIX

Protection rating

IP66

Telemetry formats

TTY 20 mA‚ RS232‚ RS422 / RS485

Auxiliary contact rating

250 V AC‚ 1 A
30 V DC‚ 2.5 A

Baud rate

(2400 to 19200 bps selectable)

Data outputs (camera control)

TTL‚ RS422 / RS485

Weight

2.85 kg

S24245-B5015-A1

CDC0502

Telemetry Receiver for Control Pan-Tilt Heads‚ Potentiometers

Weatherproof telemetry receiver for control pan-tilt units and motor-
driven zoom lenses. The drivers can be controlled either via a SIMATRIX
SYS‚ Neo‚ 648 or 164 video matrix or from the CKA3210 and CKA4820
control keyboards directly. The control unit is designed for operating
pan-and-tilt heads with a power supply of 230 V AC‚ 115 V AC or 24 V
AC. Up to 99 addresses can be selected using DIP switches. Also with
position control for zoom/focus and pan/tilt for 64 stored preset posi-
tions.
6 x M16‚ 2 x M20 and 1 x M26 glands are provided for cabling.

Address codes

99

Power requirements

230 V AC‚ 115 V AC‚ 50/60 Hz

Dimensions (W x H x D)

280 x 190 x 130 mm

Auxiliary relays

3

Compatible with

CKA3210‚ CKA4820‚ SIMATRIX

Protection rating

IP66

Telemetry formats

TTY 20 mA‚ RS232‚ RS422 / RS485

Auxiliary contact rating

250 V AC‚ 1 A
30 V DC‚ 2.5 A

Baud rate

(2400 to 19200 bps selectable)

Data outputs (camera control)

TTL‚ RS422 / RS485

Presets

64

Weight

2.85 kg

S24245-B5017-A1